ATTO Technology FastStream SC 5300 Installation And Operation Manual page 53

Storage controller, fibre channel to fibre channel & fibre channel to scsi
Hide thumbs Also See for FastStream SC 5300:
Table of Contents

Advertisement

EventLog
Regulates event logging. When enabled, the unit records
various system events to the event log.
Default: enabled
set EventLog [enabled | disabled]
get EventLog
EventLogFilter
Filters data from specific unit subsystems and levels when
EventLog
is enabled. The specific entries supported are
platform-dependent. For set commands, the final parameter
indicates whether or not events from the specified subsystem
and level are displayed.
Default: all all all
set EventLogFilter [subsystem | all] [ level | all] [all | none]
get EventLogFilter [subsystem| all ] [level | all]
Exit
Terminates the current CLI session over Telnet. This command
has no effect if used during a serial CLI session.
Exit
FCConnMode
Specifies the connection mode the unit uses when
communicating across a Fibre Channel network.
Connection modes:
FC_AL arbitrated loop: loop
Point-to-point: ptp
auto-negotiation, loop preferred: loop-ptp
auto-negotiation, ptp preferred: ptp-loop:
Default: loop
set FCConnMode [fp| all] [loop | ptp | loop-ptp | ptp-loop]
SaveConfiguration Restart command required
get FCConnMode [fp | all]
FCDataRate
Specifies the Fibre Channel data rate at which the unit operates.
Choices are 1Gb/sec., 2Gb/sec., 4Gb/sec. or Auto-negotiate.
Note
The FC data rate displayed in the
toggles between 1Gb, 2Gb and 4Gb on a 4Gb-
capable unit if no connection has been
established.
Default: auto
set FCDataRate [fp | all] [1Gb | 2Gb | 4Gb | auto]
SaveConfiguration Restart command required
get FCDataRate [fp | all]
FCHard
Regulates Fibre Channel hard address assignment. When
enabled, the unit tries to use its internal hard address as its
address on the Fibre Channel loop. Under soft addressing, the
unit loop address is assigned during loop initialization.
Default: disabled
set FCHard [enabled | disabled]
SaveConfiguration Restart command required
get FCHard
FCHardAddress
Specifies the value used as the FC-AL hard address, in
hexadecimal. This value represents the address the unit tries to
use if
FCHard
address values is 0 through 125.
Defaults: fp1=3, fp2=4, fp3=5, fp4=6
set FCHardAddress [fp] [address]
SaveConfiguration Restart command required
get FCHardAddress [fp | all]
FCMultiNode
Determines the reported identity of Fibre Channel ports. When
enabled (multiple node mode), each port reports a separate
unique Node Name; logical units may be mapped to any port.
When disabled (single node), each port reports the same Node
Name and each logical unit map is applied to all ports.
Default: disabled
set FCMultiNode [enabled | disabled]
get FCMultiNode
FCPortErrors
Displays the number of Fibre Channel errors that have occurred
since the last reboot/power-on or use of the
ResetFCPortErrors
Info
output
get FCPortErrors [fp | all]
FCPortList
Displays a list of available FC ports and their current status.
Valid reported status values are Up, Down, Failed,
Reserved and Disabled.
FCPortList
is enabled. The range of valid Fibre Channel
Note
Changing the FC port reporting causes all
maps to be deleted: you must perform a
FCTargets
command before creating new
maps using the
AutoMap
commands.
command.
or
Route
ix

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 5700

Table of Contents