CAUTION
CAUTION
All RAID group setup information is lost
and you lose all RAID group data.
BlockDevClean [BlockDevID]
BlockDevIdentify
Lights the LED of a disk drive. Use either RAID GroupName and
MemberIndex, or block ID.
BlockDevIdentify <GroupName> [BlockDevID |
MemberIndex]
BlockDevIDStop
Turns off the IO LED of a previously identified disk drive.
BlockDevIDStop
BlockDevScan
Lists all currently-connected physical block devices and any
potential RAID group association. Each block device listed is
assigned a unique index at the time of the scan which is used to
identify block devices for other CLI operations.
FastStream SC 5300 only: If you wish to force rediscovery of all
block devices, use the flush parameter. If you uses it, all
existing RAID groups are forced offline until member block
devices are discovered.
BlockDevScan <flush>
Boot Delay
Regulates the delay (in seconds) which the unit waits after
startup before allowing hosts to detect target devices. The value
0 produces no delay.
Default: 5
set BootDelay [0-255]
get BootDelay
BridgeModel
Reports specific model and firmware information.
get BridgeModel
BridgeName
Specifies an ASCII name assigned to the unit to identify
individual units. It is not the World Wide Name. Changes take
effect immediately. The name may be contain up to 8
characters.
set BridgeName [name]
SaveConfiguration Restart command required
get BridgeName
ClearEventLog
Clears the contents of the EventLog. No new entries are
recorded until the operation is completed.
ClearEventLog
Date
Regulates the current date for this unit. The date range is
1/1/2000 to 12/31/2099.
set Date [MM] / [DD] / [YYYY]
get Date
DefaultInterleave
Assigns or retrieves the system's default interleave size (in 512-
byte blocks) for new RAID groups (before
been used). If an interleave size is not explicitly specified when
a RAID group is created, then the DefaultInterleave value is
used instead.
Default: 128
set DefaultInterleave [16 | 32 | 64 | 128 | 256 | 512 | 1024
| 2048]
SaveConfiguration Restart command required
get DefaultInterleave
DeleteAllMaps
Removes all mapped devices from the map table. Upon the
subsequent POST, the default maps are loaded if no maps are
present.
DeleteAllMaps
SaveConfiguration command required
DisplayEventLog
Displays the EventLog.The event log may be filtered using the
DisplayEventLogFilter
command. The optional parameter n is
the number of lines to be displayed as a single page with no user
interaction. After the command has executed, use +, - or = to
scroll through the log. Type quit and press Enter to exit the
command.
DisplayEventLog <n>
DisplayEventLogFilter
Filters the display of data for specified subsystems and levels
during
DisplayEventLog
mode. Valid event log subsystem
entries are platform-dependent. For set commands, the final
parameter indicates whether or not events from the specified
subsystem and level are displayed.
Default: all all all
set DisplayEventLogFilter [subsystem | all] [level | all] [all
| none]
get DisplayEventLogFilter [subsystem |all] [level | all]
DriveTest
Starts or stops a drive test with the previously-specified
configuration and drive list. Drives which are in-use by the test
are not available for RAID configuration or RAID operations.
Only one test can be run at a time.
DriveTest [Begin | Cancel]
RGCommit
has
vii

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 5700