IPSubnetMask
Controls the current subnet masks used by any Ethernet port(s)
on the unit. If
IPDHCP
is enabled, the get command reports the
current IP subnet mask assigned by the network DHCP server.
Default: 255.255.0.0
set IPSubnetMask [mp1] [xxx.xxx.xxx.xxx]
SaveConfiguration Restart command required
get IPSubnetMask [mp1]
IsReserved
Displays the reservation status of the current unit.
IsReserved
MaxOpTemp
Regulates the maximum operating temperature of this unit in
degrees Celsius. Valid entries are between 55 and 70 degrees.
Default: 70
set MaxOpTemp [55 – 70]
SaveConfiguration Restart command required
get MaxOpTemp
Metrics
Controls the collection of standard data metrics within a product.
Metrics [Start | Stop | Display | Clear] [[drive [BlockDevID]
| all | running]
MinOpTemp
Regulates the minimum operating temperature of this unit in
degrees Celsius. Valid entries are between 0 and 15 degrees.
Default: 0
set MinOpTemp [0 – 15]
SaveConfiguration Restart command required
get MinOpTemp
OpTempWarn
Regulates the number of degrees Celsius before a thermal
control event precipitates a warning to the user. Valid entries are
between 0 and 15 degrees.
Default: 5
set OpTempWarn [0 – 15]
SaveConfiguration Restart command required
get OpTempWarn
Partition
Sets the specified partition to the specified capacity in gigabytes
(GB), megabytes (MB), or blocks. The specified capacity must
be smaller than the specified partition's current capacity. A new
partition is created to acquire the remainder of the original
partition's space.
VirtualDriveInfo
statistics for all the available virtual drives or any available
virtual drive identified by its virtual drive ID.
Partition [GroupName] [partition index] [capacity] [GB |
MB | blocks]
displays characteristics and
PartitionDisplay
Lists all the partitions available in the specified RAID group. The
partitions are listed in order of contiguousness (as opposed to
index order).
PartitionDisplay [GroupName]
PartitionMerge
Combines the specified contiguous partitions into one partition.
Partition index is the index of a partition to merge, along with
a number of contiguous partitions to merge to that index. All
indicates that all partitions in the RAID group are merged into a
single Virtual Disk. The RAID group must not be in a NEW state.
None of the partitions to merge may be mapped.
PartitionMerge [GroupName] [[[partition index] [2-128]] |
all]
PartitionSplit
Divides the specified partition into one or more partitions whose
capacities are evenly distributed among the capacity of the
original partition. The partition to split cannot be mapped. The
RAID group must not be in a NEW state.
PartitionSplit [GroupName] [partition index] [2-128]
PartitionWriteCache
If enabled, allows higher write performance with a small risk of
data loss after a system failure. If disabled, provides a higher
level of data integrity with lower write performance.
set PartitionWriteCache [GroupName] {PartIndex]
[enabled | disabled]
get PartitionWriteCache [GroupName] {PartIndex]
PassThroughMode
SC 5700
Specifies the non-disk device types which are automatically
mapped at boot time. The all option allows all non-disk devices
to be mapped. The SES option allows dedicated SES processor
LUNs to be mapped. The non-SES option allows all non-SES
devices to be mapped. The disabled option disables the pass-
through mode.
Default: disabled
set PassThroughMode [all | SES |non-SES | disabled]
get PassThroughMode
PassThroughPersistent
SC 5700
Stores maps for currently-attached passthrough devices to
persistent memory,
PassThroughPersistent