ATTO Technology FastStream SC 5300 Installation And Operation Manual page 52

Storage controller, fibre channel to fibre channel & fibre channel to scsi
Hide thumbs Also See for FastStream SC 5300:
Table of Contents

Advertisement

DriveTestConfig
Configures the next drive test to perform: initialize (destructive
write-only), read (non-destructive read-only), verify (destructive
verify), or init-verify (destructive write-read-verify).The test is not
started until the
DriveTest
set DriveTestConfig [init | read | verify | init-verify]
get DriveTestConfig
DriveTestList
Specifies drives to be run in the next drive test. This command
can be called with different eligible block IDs and each one is
added to the list. Drives which are not part of a RAID group or
are not hot spares are eligible. The all parameter automatically
chooses eligible drives. The test is not started until the
DriveTest
Begin command is given.
set DriveTestList [drive [BlockDevID] | all]
get DriveTestList
DriveTestStatus
Displays the status of the currently running drive test, but does
not display performance metrics. If a block device ID is not
running or cannot be found, its state is idle and percent
complete is 0.
get DriveTestStatus <drive [BlockDevID]>
DumpConfiguration
Displays the unit's configuration to the Advanced page of the
ExpressNAV Storage Manager or a terminal emulation or telnet
session. The record may not be displayed completely in the
ExpressNAV page.
DumpConfiguration
DumpEventLog
Displays the contents of the
EventLog
of the ExpressNAV Storage Manager or a terminal emulation or
telnet session. The record may not be displayed completely in
the ExpressNAV page.
DumpEventLog
EmailFromAddress
Configures the Email address that the unit uses to communicate
with the Email server. Full Email address is a fully qualified
Internet Email address, not more than 128 characters long.
set EmailFromAddress [full email address]
get EmailFromAddress
EmailNotify
Regulates Email notification.
Default: disabled.
set EmailNotify [enabled | disabled]
get EmailNotify
viii
ATTO Technology Inc. FastStream SC Installation and Operation Manual
Begin command is given.
to the Advanced page
EmailNotifyAddress
Configures notification addresses. Index is a number between 1
and 5. Full Email address is a fully qualified Internet Email
address, not more than 128 characters long. Emails are sent
based on the warning level you set to trigger an Email alert.
Warning levels
None: no Emails
Critical: only critical severity events
Warning: warnings and critical events
Informational: information
All: all warnings, critical events and informational
messages
set EmailNotifyAddress [index] [full email address]
[warning level]
get EmailNotifyAddress <index | all>
EmailPassword
Configures the password which authenticates the login to the
SMTP Email server. The password must not be more than 64
characters. A password is not required if the Email server does
not require authentication.
set EmailPassword
SaveConfiguration command required
EmailServerAddress
Configures the address of the server the unit must contact in
order to send out Email notifications using either an Email
address (xxx.xxx.x.x) or a fully qualified domain name
(mal.myserver.com).
Default: 0.0.0.0
set EmailServerAddress [IP address |domain name]
SaveConfiguration command required
get EmailServerAddress
EmailUsername
Configures the user name which authenticates the login to the
SMTP Email server. The user name must not be more than 128
characters. A user name is not required if the Email server does
not require authentication.
set EmailUsername [username]
SaveConfiguration command required
get EmailUsername
EthernetSpeed
Regulates the speed of the unit's Ethernet port(s). If Auto is
enabled, the Ethernet speed is negotiated. When hard set, 10
and 100 speeds are half duplex.
Default: auto
set EthernetSpeed [mp1] [10 | 100 | auto]
SaveConfiguration Restart command required
get EthernetSpeed [mp1]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 5700

Table of Contents