Specifications of Serial Absolute Encoders of Nemicon
-
Current consumption of battery
during backup operation
-
Backup time
Ambient Conditions
-
Temperature during operation
and stop
-
Humidity
Specifications of Absolute Signals (Serial Communication)
-
Transmission standard
-
Transmission method
-
Data length
-
Transmission cycle
-
Transmission distance
-
Type of modem for receiving
-
Data transmission format
:
Typical
40 micro-amps
After charging for longer than 10 minutes
at ambient temperature of 20 degree C
and Vcc = 5 V.
:
Minimum 3.8 hours
After charging for longer than 3 minutes
at Vcc = 5 V.
:
-20 to 85 degree C (-4 to 185 degree F)
of board temperature
:
Less than 95% RH (ambient temperature
less than 40 degree C) (no condensation)
:
RS-422A (IEA standard)
:
Converted by Manchester coding and
transmitted synchronously; containing
CRC error checking function
:
32 bits (16 bits x 2)
:
84 microseconds (typical)
(modem clock 8 MHz)
:
Maximum 50 meters
:
DN1811B (Mitsubishi Electric Corp.)
:
Transmitted by dividing 32-bit data to two
of 16-bit data