Reliance electric S-D4024 Engineering Manual page 46

Absolute encoder input card
Table of Contents

Advertisement

F-2
Maximum Absolute Rating
-
Main power voltage
-
External battery voltage
-
Voltage at clearing terminal
-
Output current of line driver
Electrical Characteristics (Standard Ta = 25 degree C)
-
Main power voltage
-
Battery voltage
-
Operation Mode Switching Voltage
-
From usual operation to
backup operation
-
From backup operation to
usual operation
-
Rasing voltage of system down :
-
Rasing voltage of battery alarm :
-
Clearing time
-
Time period to be required for
sending data
-
Power board temperature
-
Response rotating speed
-
From stop to usual operation,
and from backup operation to
usual operation
-
During usual operation and
backup operation
-
Current consumption during
usual operation (when transmission
line is open)
:
-0.3 to 6.0 V
:
-0.3 to 5.5 V
:
-0.3 to 6.0 V
:
OH: –20 milli-amps
OL: 20 milli-amps
:
Minimum
4.75 V
Maximum
5.25 V
Typical
5.0 V
With ripple content less than 1%
:
During back up operation:
Minimum
3.0 V
Typical
3.6 V
:
Typical
4.1 V
:
Typical
4.3 V
Internal capacitor voltage or external
battery voltage whichever is higher:
Typical 2.8 V
External battery voltage: Typical 3.0 V
:
Minimum
3.2 seconds
:
Maximum
0.3 seconds
After moved to usual operation.
Power supply impedance = 0
:
Minimum
-20 degree C
Maximum
85 degree C
:
Maximum
300 r/min
:
Maximum
6000 r/min
:
During capacitor is discharging:
Maximum
140 milli-amps
During usual operation:
Maximum
120 milli-amps
PSC5000 Serial Absolute Encoder Input Card II S-D4024