Specifications of Serial Absolute Encoder of IHI
-
Backup time of internal secondary
lithium battery
-
Life of external battery
(per one axis)
Ambient Conditions
-
Operating temperature
-
Storage temperature
-
Humidity
Communication of Absolute Signals
-
Transmission line
-
Transmission method
-
Data length
-
Transmission cycle
-
Transmission distance
-
Type of modem
-
Data transmission format
* 1: Be careful that the specifications may be changed without notice.
2: The maximum transmission distance depends on size of cable wire. Use the
following recommended cable or equivalent:
Model M-53004 of Reliance Electric (size of wire 0.05 square millimeters,
twisted pair, seven pairs are shielded as a lot)
The above-mentioned maximum transmission distance of 200 meters is
obtained when the above cable is used.
3: When power wiring for encoders is installed in a same conduit, be careful to
acquire the required voltage at the encoders, considering voltage drop due
to cable length.
:
Minimum
48 hours
When the internal battery was charged for
longer than 24 hours with Vcc of 4.75 V
:
Minimum
2 years
Typical
6 years
Lithium cell ER17/33 of Hitachi-Maxwell
3.6 VDC, 1500 milli-amps-hours
:
-10 to 70 degree C (14 to 158 degree F)
of case temperature
:
-20 to 80 degree C (-4 to 176 degree F)
:
Less than 90% RH (no condensation)
:
RS-422A (IEA standard)
:
Converted by Manchester coding and
transmitted synchronously; containing
CRC error checking function
:
32 bits (24 bits of absolute data + 8 bits
of status data)
:
84 microseconds
:
Maximum 200 meters *
:
DN1811
:
Transmitted by dividing 32-bit data to two
of 16-bit data
D-3