Technical Specifications - Beretta Power X 35 Installation Manual

Hide thumbs Also See for Power X 35:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 36

2 6 Technical specifications

Description
Certifications
Boiler typology
CE certification no.
Encumbrances
Height x Width x Depth
Loadless boiler weight
Water capacity
Delivery/Return/Gas connections
Flue gas discharge (twin)
Power and efficiency
Maximum rated heat input Hi/Hs
Minimum rated heat input Hi/Hs
Nominal power supplied to the water (80°C - 60°C)
Nominal power supplied to the water (50°C - 30°C)
Efficiency at 100% nominal power (80°C - 60°C)
Efficiency at 30% nominal power (80°C - 60°C)
Efficiency at 100% nominal power (50°C - 30°C)
Efficiency at 30% nominal power (50°C - 30°C)
Fuel and power supply
Fuels
Gas intake flow rate at nominal pressure G20/G30/G31
Electrical power supply/Electrical insulation rating
Fan power consumption
Circulator power consumption
Combustion data
Combustion efficiency at Nominal power (80°C - 60°C)
Combustion efficiency at Nominal power (50°C - 30°C)
Flue heat loss with burner on at 100% Nominal power
(80 - 60°C)/(50 - 30°C)
Chimney and skirt losses with burner off
Casing heat loss with the burner on at 100% Nominal
power
Flue gas temperature at maximum heat input
Flue gas flow rate at maximum/minimum heat input
Residual flue gas discharge head at Nominal power
(meq per D80 mm)
CO2 at maximum/minimum heat input (G20)
CO at maximum/minimum heat input
NOx at maximum/minimum heat input
NOx Class
Heating system
Min/max settable temperature
Max operating pressure
Residual water discharge head at 1000 l/h
Hourly condensate production at 100% Nominal power
(50°C - 30°C)
POWER X
50 DEP / 50
35 / 35 R.S.I.
DEP R.S.I.
C13, C13x; C33, C33x; C43, C43x; C53, C53x;
C63, C63x; C83, C83x
0085AQ0713
915 x 510 x 375
50
55
4,1
4,8
1"-1"-3/4"
80
31,5/35,0
34,8/38,6
5,2/5,8
13,5/15,0
30,90
34.37
34,00
37.70
98,00
98,20
97,99
98,70
108,13
107,70
109,20
108,70
3,33/2,48/2,45
3,71/2,82/2,78
80
85
60
98,7
98,7
99,39
99,1
1,3/0,61
1,3/0,9
0,1
0,1
0,2
0,5
Return T° + max 5°C
52,3/8,4
56,1/23,2
323/50
334/50
9,0/9,0
100/15,8
56/8
25/5,7
22/10,7
V (fifth)
10/80
3
0,6
0,6
4,8
5,1
ENGLISH
50 / 50 R.S.I.
mm
55
kg
4,8
l
mm
45,0/50,0
kW
13,5/15,0
kW
44,20
kW
48,50
kW
98,20
%
98,70
%
107,70
%
108,70
%
4,77/3,63/3,57
mc-kg/h
100
W
W
98,7
%
99,1
%
1,3/0,9
%
0,1
%
0,5
%
°C
72,51/23,2
Kg/h
490/50
Pa/meq
%
64/8
ppm
24/10,7
ppm
°C
bar
0,6
bar
6,6
l/h
43