Main rulings of applicable standards, predict that:
Interior hose diameter should be 8mm.
To connection the hose use a standard clamps.
Check if the hose i connedted properly on both endings.
The hose should not touch in any point with hot parts of gas cooker.
The hose should not be longer than 1,5m.
The hose should not be in any point bended or stretched, along its entire length it should also
not have bends or narrowings.
Along its lenght, the hose should be accessible, so that its wear can be checked.
In case of leaking the hose should be replaced. It is forbidden to repair damaged hose.
ATTENTION:
After the installation of gas cooker, it should be checked if there is no leaking on all connections, please
use water with soap.
DO NOT USE FLAME TO CHECK LEAKAGES.

CONNECTION THE COOKER TO THE POWER SUPPLY SYSTEM

The cooker is factory-set for single-phase alternating current (230V 1N ~50Hz) and equipped
with a 3 x 1,5mm2 connecting cable with length of about 1,5m with a plug with protective
contact.
The electrical connection socket must be equipped with a protective pin and must not
be located above the cooker. The positioning of the cooker requires that the electrical
connection socket is accessible to the user.
Before connecting the cooker to electrical socket ensure that:
- Fuse and power supply system holds on the electrical loads of the cooker.
- The powerr supply system is equipped with efficient grounding system corresponding to the
current regulations.
- The plug is located in easily accssesible place.
ATTENTION:
If the non detachable power cable will damage, it should be repalced at the manufacturer or in the
specialist repair shop, or by the qualificated technician to prevent the danger.

ADJUSTING THE COOKER TO DIFFERENT TYPE OF GAS

This performace may be conducted only by the qualifictaed technician. If gas, which cooker will
be supplied with, is different from the factory-set gas option (G20 2E 20 mbar), it should be replaced
burner nozzles and conduct the regulation of flame.