1-5-4. Connecting/Disconnecting Coaxial Cable for SDI 1, 2

Tip
When disconnecting and reconnecting the coaxial cables for SDI 1 and SDI 2 of HDC-P50, refer to this section.
Coaxial Cable
SDI 1: COAXIAL CABLE (D.FL75) (SDI 1) (Part No.: 1-912-828-12)
SDI 2: COAXIAL CABLE (D.FL75) (SDI 2) (Part No.: 1-912-874-12)
Required Tool
D.FL75-LP-N75 connector extraction tool: Part No.: J-7121-700-A
Disconnecting
1.
Insert the tip of the connector extraction tool into the connector area of the coaxial cable in the direction of the arrow A.
2.
Pull up the connector extraction tool upwards in the direction of the arrow B to disconnect the connector.
Note
Do not pull the cable of the coaxial cable.
Connector extraction tool
Coaxial cable
B
A
Connecting
1.
Hold the plug of the coaxial cable.
2.
Push the plug vertical to the connecting connector turning it clockwise and counterclockwise.
Hold the plug to connect
Connecting connector
Connecting connector
Connecting connector
20