7-5. Reference File

Reference files can be stored in the camera and USB drive.
Reference files can also be stored in the memory stick if the master setup unit (MSU) is used. For details, refer to the MSU operation
manual.
Data is stored and called using the setup menu or MSU.
Reference files can be copied between cameras using the USB drive.
Note
Reference File stores the differential data taking the factory-setting as 0. Therefore, initializing the Reference File brings the settings
to the same status at the factory setting. If Lens File or OHB File retains the data, they need to be initialized as well.
To initialize data, use the setup menu. You can select all file items or only specified items to initialize.

7-5-1. Reference File Operation

Outline figure of operation
Camera unit
Current paint data
Output to hardware
Storing
Reference: Refer to step 1 of "Outline Figure of Operation".
Using FILE menu of this unit
Reference file is stored in the camera and the numerical data is displayed as 0. (Excluding some items. Refer to "7-8. File Items".)
[FILE] → [REFERENCE] → [STORE FILE]
With MSU (master setup unit)
1.
Press the FILE button in the functional operation area on the operation panel.
Select [Reference] → [Reference Store] by the menu operation.
2.
Reference file is stored in the camera and the numerical data is displayed as 0. (Excluding some items. Refer to "7-8. File
Items".)
Calling
Reference: Refer to step 2 of "Outline Figure of Operation". Refer to "7-1-1. Structure of Paint Related Files".
Using PAINT menu of this unit
Temporary paint (values of each item) and selection of scene file are reset, and the state when the reference file was stored is
resumed.
[PAINT] →[SCENE FILE] → [STANDARD]
With MSU (master setup unit)
Pressing the STANDARD button in the camera/panel control area on the operation panel restores the state when the reference file
was stored.
USB drive
Storing in
Reading from
USB drive
USB drive
(Step 4)
Storing
(Step 1)
Referenc File
Calling
(Step 2)
(Step 3)
Initializing
Reference File
(Step 5)
factory-set value
(Initial value 0)