5-4-2. Detail Level Adjustment

Equipment: Waveform monitor (R, G, B)
Test Point: SDI 1 connector
Object: Grayscale chart
Preparation
Setting for the MSU
DETAIL OFF button → ON (unlit)
KNEE OFF button → OFF (lit)
Shoot the grayscale chart so that it is aligned with the under scanned monitor frame.
Lens iris: F4 to F5.6
A = 600 ±20 mV
If the lens aperture is greater than F5.6, adjust the light amount with the shutter.
Procedure
1.
Operate the control panel of MSU, and set as follows.
(1) PAINT button → ON (lit)
(2) Touch panel operation: (Page 1) → [Detail] → [1/3]
2.
Adjust the detail level to be added to each step of the grayscale to the desired level.
Adjustment item: [Level]
3.
Store the reference file.
(Refer to "5-4-12. File Store".)
A
84