5-1-5. Connection of Equipment

Multi purpose camera
Lens
HDC-P50/P31
(for ENG/EFP)
Master setup unit
MSU-1000/1500/3000/3500

5-1-6. Initial Settings

There are following Initial Settings.
Set using the MSU.
Set using setup menu and switches of the camera.
Before starting "5-2. Automatic Adjustment" or later, perform the initial setting.
When adjusting with the MSU
Set each button on the MSU as follows.
Power supply and signal switching block
ALL button → OFF (unlit)
-
CAM PW button → ON(lit)
-
VF PW button → OFF (unlit)
-
TEST 1 button → OFF (unlit)
-
TEST 2 button → OFF (unlit)
-
BARS button → OFF (unlit)
-
CLOSE button → ON(lit)
-
Camera/CCU circuit ON/OFF block
KNEE OFF button → OFF(lit)
-
DETAIL OFF button → OFF(lit)
-
MATRIX OFF button → OFF(lit)
-
AUTO KNEE button → OFF (unlit)
-
SKIN DETAIL button → OFF (unlit)
-
Others
GAMMA OFF button → ON (unlit)
-
MASTER GAIN → 0 (0 dB)
-
FILTER button (ND) → 1 (CLEAR)
-
FILTER button (CC) →B (3200K)
-
ON button (shutter control block) → OFF (unlit)
-
A-ch
SDI MONI
CCA-5 cable
(max. 200 m)
Waveform monitor
Y, Pb, Pr
R, G, B
HD Color monitor
73