Summary of Contents for Belmont EURUS SWIVEL CHAIR
Page 1
DENTAL CHAIR (FOLDING LEGREST TYPE) INSTRUCTIONS FOR USE...
Page 2
Dear Customers Dear Customers Thank you for purchasing our product. This booklet explains how to use DENTAL CHAIR (FOLDING LEGREST TYPE). Before using DENTAL CHAIR (FOLDING LEGREST TYPE), carefully read the operating instructions and make sure to use the product correctly. Using the product without reading these instructions may lead to an accident.
2-2-1 Points to remember when operating the product 2-3 EMC Information 2-4 Devices Connectable to the Product Precautions for Use 3-1 Operating Precautions 3-2 Precautions for Using Synthetic Leathers Specifications and Operation 4-1 EURUS SWIVEL CHAIR 4-1-1 Specifications 4-1-2 Dimensions 4-1-3 Name of Each Part 4-1-3-1 Chair 4-1-3-2 Headrest 4-1-4 Operation 4-1-4-1 Prepation Before Use...
Page 4
Table of Contents Specifications and Operation 4-1-4-8 Operating the Legrest 4-1-4-9 Chair Rotation 4-1-4-10 Turning the armrest 4-1-4-11 Cancellation function 4-1-4-12 Chair lock function 4-1-4-13 Setting the treatment and entry/exit positions 4-1-4-14 Setting the mouth rinsing position 4-2 CLAIR CHAIR 4-2-1 Specifications 4-2-2 Dimensions 4-2-3 Name of Each Part 4-2-3-1 Chair 4-2-3-2 Headrest 4-2-4 Operation 4-2-4-1 Prepation Before Use...
Page 5
Table of Contents Maintenance by Service Engineers 6-1 After-sales Service 6-2 Service Life 6-3 Period of Parts Retention Troubleshooting 7-1 Troubleshooting Accessories and Consumables 8-1 Accessories 8-2 Consumables Graphic Area Texts Area...
MDR (EU) 2017/745 and RoHS Directive 2011/65/EU based on category 8 of Annex I. Product : DENTAL CHAIR (CLASS I) Model : EURUS SWIVEL CHAIR CLAIR CHAIR " CLASS I " has been defined by the rule 13 of MDR Annex XIII.
General Information Recomendation to user A notice to the user and/or patient that any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user and/or patient is established.
General Information Product name Rated voltage ① ① Maximum activation time ② Rated input ② Non-continuous operation ③ Duty cycle ③ Product of Japan Technical Description The following are explained in the documents listed below: Item Document How to install this product Installation Instructions Wiring/flow diagram Installation Instructions...
Safety Consideration Risk Level Interpretation Precautions before use Make sure to carefully read the Safety Precautions and Operating Precautions and use the product correctly. These precautions are intended to ensure the safe use of the product and prevent harm or damage to users or other people. According to the magnitude of harm and damage and the degree of urgency, an incident that may be caused by misuse of the product is classified into one of the following categories: CONTRAINDICATION,...
Page 11
Safety Consideration Classification by degree of CONTRAINDICATION harm or damage and urgency Use of the product without regard to this indication will create a hazardous condition that may result in death or serious injury. WARNING Improper handling of the product without regard to this indication will create a hazardous condition that may result in death or serious injury.
HF surgical equipment may cause incorrect operation of this product. Never disassemble, repair or modify the product. Individuals other than your local authorized Belmont dealer should not disassemble or repair this product. This could lead to an accident, failure, electric shock, or fire.
Page 13
Safety Consideration WARNING Power Plug and Cord Do not connect the earth (ground) to the following objects. Water pipes • (Complete grounding is not possible as hard plastic pipes are widely used.) Gas pipes (Can result in an explosion or fire) •...
Page 14
Safety Consideration WARNING Power Plug and Cord Securely connect to ground. Failure to make a ground connection can result in electric shock if there is a malfunction or short circuit. Consult an electrician for grounding procedures. Unplug the power plug when the chair is not in use. Turn off the power switch and remove the power plug from the socket when the chair is not in use.
Page 15
Installing or transferring Precautions for installation the product Ask your local authorized Belmont dealer to install the product. Make sure to place the product on a firm and flat floor. Placing the equipment on a non-flat floor may cause it to fall.
Page 16
Safety Consideration WARNING Use and maintenance Perform cleaning before using the product for the first time. This product is not sterilized or disinfected when shipped. of the product Remove the patient’s glasses and any accessories (such as a necklace or bracelets) before treatment. Failure to follow this instruction may hamper treatment and lead to an accident.
Page 17
Safety Consideration WARNING Use and maintenance Precautions for getting on and off this product When the patient gets on or off this product, the chair should always of the product be at the lowest position with the backrest at upright position and with the rotation being locked by the lock pedal.
Page 18
Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm(12 inches) to any part of EURUS SWIVEL CHAIR/ CLAIR CHAIR, including cables specified by the manufacturer. Otherwise,degradation of the performance of this equipment could...
Page 19
Discontinue use of the product if it is broken. In the case of a broken product, immediately discontinue use and turn off the main switch. Then, ask your local authorized Belmont dealer to repair the product. Be sure to turn off the breaker for devices when the product is not used for a long period of time.
Page 20
If you feel something is wrong, immediately discontinue use of the product and turn off the main switch. Then, contact your local authorized Belmont dealer. Read the Instructions for use. Before use, make sure to carefully read the instructions for use and use the device correctly.
Safety Consideration CAUTION Use and maintenance Immediately wipe off any drug solutions or water adhered to the product. of the product Adherence of drug solutions or water to the product may cause operational failure or electrical leak. If drug solutions or water are adhered, immediately turn off the main switch and wipe them off with a dry, soft cloth.
Safety Consideration EMC Information This product complies with EMC Standard EN60601-1-2:2015. 1. Precautions regarding EMC and compliance with accompanying documents Medical electrical equipment requires special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in this booklet.
Page 23
Safety Consideration 5. Electromagnetic immunity declaration 1 Guidance and manufacturer’s declaration—electromagnetic immunity This product is intended for use in the electromagnetic environment specified below.The customer or user of this product should ensure that it is used in such an environment. IEC 60601 Electromagnetic environment Immunity test...
Page 24
Safety Consideration 6. Electromagnetic immunity declaration 2 Guidance and manufacturer’s declaration—electromagnetic immunity This product is intended for use in the electromagnetic environment specified below.The customer or user of this product should ensure that it is used in such an environment. IEC 60601 Electromagnetic environment Immunity test...
Page 25
Safety Consideration Near electromagnetic field caused by RF wireless communication devices Test frequency Modulation IEC 60601 IEC 60601 test level compliance level (MHz) Pulse modulation 27V/m 27V/m 18Hz Frequency modulation 28V/m 28V/m ±5kHz shift 1kHz sine wave Pulse modulation 9V/m 9V/m 217Hz Pulse modulation...
Safety Consideration Devices Connectable to the Product Use this product in combination with the unit marked with a circle. Devices connectable TYPE CLESTA II / CELEB EURUS SWIVEL CHAIR ○ CLAIR CHAIR...
Precautions for Use Operating Precautions Immediately wipe off any drug solutions adhered to the product. Otherwise, they may cause deterioration or discoloration. Do not apply heat to this product. This may cause deterioration or discoloration. Discoloration of resin Resin materials are used in external components of the product. Carefully selected materials are used;...
Precautions for Use Precautions for Using Synthetic Leathers Adherence of clothing dye To clean and disinfect the synthetic leathers, wipe the surface with a soft cloth or paper towel moistened with FD360 manufactured by Dürr, and then wipe it with a dry cloth. Dye may migrate from clothes or belts to the synthetic leathers of the product.
Specifications and Operation EURUS SWIVEL CHAIR 4-1-1 Specifications Model No. ……………………… AC-ERS-FD* (* represents single or multiple strings or numbers. ) Classification for protection …… Class I equipment against electric shock Classification according to the … B-type isolated applied parts...
Page 30
Specifications and Operation Model No. ……………………… AC-ERS-FP* (* represents single or multiple strings or numbers. ) Classification for protection …… Class I equipment against electric shock Classification according to the … B-type isolated applied parts degree of protection against (leather-covered parts) electric shock Rated Power Supply ……………...
Page 31
Specifications and Operation Name of Each Part 4-1-3 4-1-3-1 Chair Headrest Backrest Armrest Seat Base Roll up Legrest Legrest Rotation lock pedal 4-1-3-2 Headrest Manual Headrest Type Manual Headrest Type Power Headrest Type Power Headrest Type Stick Switch for Stick Switch for Manual Operation Headrest Operation Stick Switch for...
Page 32
Specifications and Operation 4-1-4 Operation 4-1-4-1 Preparation Before Use Inserting the power plug into the socket Socket (With ground terminal) Power plug Power cord WARNING Use an unshared socket with an attached ground terminal. Be sure to fully insert the power plug into the socket until reaching the base of the plug.
Page 33
Specifications and Operation Turning on the power (○ mark) (|mark) CAUTION Operate the main switch for chair by hand. 4-1-4-2 After use Turn off the power for chair (○ mark) (|mark) CAUTION Operate the main switch for chair by hand.
Page 34
Specifications and Operation 4-1-4-3 Raising/lowering the chair and raising/reclining the backrest (manual operation) Manual Headrest Type Manual Headrest Type Stick switch Operation Pushing direction Label indication Stick Switch for Manual Operation Power Headrest Type Power Headrest Type *The chair is operated while the stick switch is pushed down or the switch is pressed.
Page 35
Specifications and Operation 4-1-4-4 Moving the chair to the preset position (automatic operation) Manual Headrest Manual Headrest Type Type Stick switch Operation Label indication Pushing direction “Treatment position 1”. “Treatment position 2”. Stick Switch for Auto Operation Power Headrest Power Headrest Type Type “Entry/exit position”.
Page 36
Specifications and Operation 4-1-4-5 Operating the headrest (manual type) Adjustment of the headrest The headrest is capable of flexibly adjusting the inclination of the patient’s head for treatment in the upper/lower jaw. It is also possible to manually extend/fold the headrest in accordance with the patient’s height.
Page 37
Specifications and Operation 4-1-4-6 Operating the headrest (electrohydraulic type) Stick switch Power Headrest Operation Pushing direction Label indication Extend Lower Raise Stick Switch for Headrest Operation Recline *The chair is operated while the stick switch is pushed down. Do not apply an excessive load or impact on the headrest. Otherwise, failure may result.
Page 38
Specifications and Operation 4-1-4-7 Relationship among the angles of the backrest, legrest and roll up legrest Manual Headrest Type Manual Headrest Type Up tilt Limit position At the range 3&4 of backrest angle the rollup extends When the backrest angle is in: Range 4 Lay flat Range 3...
Specifications and Operation 4-1-4-8 Operating the Legrest "Legrest operation mode" controls the legrest operation. Manual Headrest Type Manual Headrest Type Power Headrest Type Power Headrest Type 1 legrest operation mode activatioin Beeps from Another beeps from 5 seconds 8 seconds Keep pushing Do not leave the stick switch for auto operation while the beeps are sounding.
Specifications and Operation 4-1-4-9 Chair Rotation Left side: Right side: Rotation is unlocked Rotation is locked Rotation lock pedal Backrest Armrest Hold the backrest or armrests when rotating the chair. When the patient sits on or gets out of the seat, be sure to put the WARNING product in the entry/exit position (seat is lowered to the bottom, the backrest is raised, and the rotating mechanism is locked).
Specifications and Operation 4-1-4-10 Turning the armrest If the armrest hinders entry/exit or diagnosis, it may be turned backward. Both the left and right armrests can be turned. Armrest (Normal position) CAUTION When turning the armrest, confirm that there is no obstruction. Operator must be careful not to get their hand or finger caught.
Specifications and Operation 4-1-4-11 Cancellation function To stop the chair movement started by a switch for automatic opera- tion (preset switch, automatic return switch, last position switch, or stick switch for automatic operation), perform one of the following operations. Operate one of the stick switches (indicated with ○). Stick Switch 4-1-4-12 Chair lock function...
Specifications and Operation 4-1-4-13 Setting the treatment and entry/exit positions Manual Headrest Type Manual Headrest Type Power Headrest Type Power Headrest Type Set the treatment position by chair manual switch Manual Headrest Type Manual Headrest Type Power Headrest Type Power Headrest Type Keep pressing 5seconds.
Specifications and Operation CLAIR CHAIR 4-2-1 Specifications Model No. ……………………… AC-CLR-230* (* represents single or multiple strings or numbers. ) Classification according to the… Type B applied part : Seat for chair degree of protection against electric shock Rated Power Supply …………… AC230V 50/60Hz 2.0A Fuse ……………………………...
Specifications and Operation Name of Each Part 4-2-3 4-2-3-1 Chair Headrest Backrest Armrest Seat RollupLegrest P.C.Board Footrest Box Cover 4-2-3-2 Headrest Manual Headrest Type Manual Headrest Type Power Headrest Type Power Headrest Type PowerHeadrest Twin Axis Headrest Stick Switch Stick Switch Power for Manual Stick Switch...
Specifications and Operation 4-2-4 Operation 4-2-4-1 Preparation Before Use Turning on the power (○ mark) (|mark) CAUTION Operate the main switch for chair by hand. 4-2-4-2 After use Turn off the power for chair (○ mark) (|mark) CAUTION Operate the main switch for chair by hand.
Specifications and Operation 4-2-4-3 Raising/lowering the chair and raising/reclining the backrest (manual operation) Manual Headrest Type Manual Headrest Type Stick switch Operation Pushing direction Label indication Stick Switch for Manual Operation Power Headrest Type Power Headrest Type *The chair is operated while the stick switch is pushed down or the switch is pressed.
Specifications and Operation 4-2-4-4 Moving the chair to the preset position (automatic operation) Manual Headrest Manual Headrest Type Type Stick switch Operation Label indication Pushing direction “Treatment position 1”. “Treatment position 2”. Stick Switch for Auto Operation Power Headrest Power Headrest Type Type “Entry/exit position”.
Specifications and Operation 4-2-4-5 Operating the headrest (manual type) Adjustment of the headrest The headrest is capable of flexibly adjusting the inclination of the patient’s head for treatment in the upper/lower jaw. It is also possible to manually extend/fold the headrest in accordance with the patient’s height.
Specifications and Operation 4-2-4-6 Operating the headrest (Power Headrest Type) Stick switch Operation Pushing direction Label indication Extend Power Headrest Lower Raise Stick Switch for Headrest Operation Recline *The chair is operated while the stick switch is pushed down. Do not apply an excessive load or impact on the headrest. Otherwise, failure may result.
Page 51
Specifications and Operation 4-2-4-7 Relationship among the angles of the backrest, legrest and roll up legrest Manual Headrest Type Manual Headrest Type Up tilt Limit position At the range 3&4 of backrest angle the rollup extends When the backrest angle is in: Range 4 Lay flat Range 3...
Specifications and Operation 4-2-4-8 Turning the armrest If the armrest hinders entry/exit or diagnosis, it may be turned backward. Both the left and right armrests can be turned. Armrest (Normal position) CAUTION When turning the armrest, confirm that there is no obstruction. Operator must be careful not to get their hand or finger caught.
Specifications and Operation 4-2-4-9 Cancellation function To stop the chair movement started by a switch for automatic opera- tion (preset switch, automatic return switch, last position switch, or stick switch for automatic operation), perform one of the following operations. Operate one of the stick switches (indicated with ○). Stick Switch 4-2-4-10 Chair lock function...
Specifications and Operation 4-2-4-11 Setting the treatment and entry/exit positions Manual Headrest Type Manual Headrest Type Power Headrest Type Power Headrest Type Set the treatment position by chair manual switch Manual Headrest Type Manual Headrest Type Power Headrest Type Power Headrest Type Keep pressing 5seconds.
Maintenance and Cleaning by Dental Staff Methods for Care Clean this chair after use to maintain it in a clean state. Turn off the power switch and unplug the power plug before cleaning. WARNING Failure to do so can result in electric shock or fire. Also, sudden movement of the chair while cleaning can result in injury.
Unexpected personal Contact your local authorized tion of the start the stick switches is pushed injury and troubles may Belmont dealer if any abnor- cancel during auto operation. arise due to motion of mality arises. function for the chair during medical...
List of consumables required for periodic inspection Parts Description O-ring, Packing WARNING Always entrust periodic inspection to your local authorized Belmont dealer. If you do not carry out periodic inspection, use of the product may cause injury or damage to nearby devices. Storage method In case of not using the product for a long period, store it in the following conditions.
Maintenance and Cleaning by Dental Staff Environmental Conditions for Transportation or Packaging (1) Environmental conditions for the transportation or packaging for Estorage of the product shall be as specified below. Temperature -20 ~ 70ºC Humidity 10 ~ 95% Air pressure 700 ~ 1060 hPa (2) Pay attention to the following items for the storage area.
Refer to ‘Troubleshooting’ before you check the device. If the problem persists, turn off the main switch, and contact your local authorized Belmont dealer to request a repair. Service Life The service life of this product is 10 years on condition that maintenance and inspection are properly conducted [according to our self-certification (our data)].
If you encounter any of the problems listed below, take the countermeasures described below before requesting a repair. If the problem persists even after troubleshooting, stop using the product immediately, turn off the power switch, and contact your local authorized Belmont dealer. Problem Check Points Recovery Procedures...
Accessories and Consumables Accessories Check that all the following accessories are present. If anything is missing or damaged, contact your local authorized Belmont dealer. ・IFU information ・Installation Instructions Consumables Consumables are parts that will normally wear or deteriorate, change their appearance, or become damaged after use.
Page 62
TAKARA COMPANY EUROPE GmbH Berner Strasse 18, 60437 Frankfurt am Main, Germany TEL : +49-69-506878-0 FAX : +49-69-506878-20 TAKARA BELMONT CORPORATION 2-1-1, Higashishinsaibashi,Chuo-ku,Osaka, 542-0083, Japan TEL : +81-6-6213-5945 FAX : +81-6-6212-3680...
Need help?
Do you have a question about the EURUS SWIVEL CHAIR and is the answer not in the manual?
Questions and answers