Pavone Systems DAT 1400 Technical Manual page 76

Weight transmitter/indicator with rs232 serial, analog and fieldbus output
Table of Contents

Advertisement

77-78
38
Input 1 mode —Logic
79-80
39
Input 1 mode —Polarity
81-82
40
Input 1 mode —Stability
83-84
41
Hysteresis input 1
85-86
42
Timing input 1
87-88
43
Delay input 1
89-90
44
Input 2 mode —Function
91-92
45
Input 2 mode —Logic
93-94
46
Input 2 mode —Polarity
95-96
47
Input 2 mode —Stability
97-98
48
Hysteresis input 2
99-100
49
Timing input 2
101-102
50
Delay input 2
103-104
51
Analogue Fixed Tare (MSB)
105-106
52
Analogue Fixed Tare (LSB)
107-108
53
Analogue Full Scale (MSB)
109-110
54
Analogue Full Scale (LSB)
111-112
55
Analogue Output Mode
113-114
56
Analogue Output Range
(*) These registers can only be modified in FREE mode or if in METRIC mode with a calibration
bridge enabled.
WRITING EXAMPLES
To write the set-up parameters following the example:
In the bytes 1-2 (Command Register) write value Hex 3FFF. This value opens the writing area of the
DAT 1400.
Example: to change the default values of the DAT 1400 like the Capacity of the load cells, the Sensitivity
and Division value to 15000, 2.9965 and 2:
Capacity
Byte 17
Hex
00
Dec
Sensitivity
Byte 21
Hex
75
Dec
29965
Division
Byte 23
Hex
00
Dec
Save the data by writing the value Hex 7 in Command Register.
N.B. The DAT 1400 does not accept writing of the same values already written.
To perform Zero and FS Calibration it is not needed to abilitate the internal Writing Area of the DAT
1400.
Zero Calibration:
Whit empty system put Hex 4 in Command Register (bytes 1-2). The new Zero value is stored.
Page 74
Byte 18
Byte 19
00
3A
15000
Byte 22
0D
Byte 24
0D
13
See correspondence on page 43
See correspondence on page 44
See correspondence on page 44
INT. value
INT. value
INT. value
See correspondence on page 44
See correspondence on page 45
See correspondence on page 45
See correspondence on page 45
INT. value
INT. value
INT. value
INT. value - Most significant word
INT. value - Less significant word
INT. value - Most significant word
INT. value - Less significant word
See correspondence on page 35
See correspondence on page 35