SLAVE TRANSMISSION PROTOCOL
LIST OF THE CONTROLS AVAILABLE:
1. Request for the net and gross weight and current peak.
2. Execution weghing command
3. Autotare command
4. Zero command
5. Peak reset command
6. Programming two weight setpoints
7. Requesting the programmed setpoints.
8. Logic output activation
9. Request Input status
10. Command of setpoints storage in permanent memory.
11. Change in net weight.
12. Change in gross weight.
13. DeleteTare command.
14. Request for Net weight.
15. Request for Gross weight.
The unit connected to the instrument (typically a personal computer) acts as a MASTER and is the only
unit that can start a process of communication.
The process of communication must be made by the transmission of a string by the MASTER, followed
by a reply from the SLAVE concerned.
CONTROLS FORMAT DESCRIPTION:
The double quotes enclose constant characters (observe upper and lower case); the < and > symbols
contain variable numeric fields. The <addr> is the instrument identification. In case of communication
on the RS485 port, is obtained by adding 80h to the instrument's address value (for example with ad-
dress 3 <addr> = 80h + 03h = 83h). In case of communication on the RS232 port, the <addr> must
always be equal to 81h, or, in case of communication on the Ethernet port, the <addr> must always
be equal to FFh
1.REQUEST FOR THE NET AND GROSS WEIGHT AND CURRENT PEAK
Master: <Addr> "N" EOT
DAT 400: "N" <Addr> <status> <net> <gross> <peak> ETX <chksum> EOT
2 EXECUTION WEIGHIN COMMAND
This command is only available in case of METRIC operation. The possible use conditions are:
• Stable weight.
• Since the last executed weigh, the weight has undergone a change of at least 20 divisions (delta
weight).
• Gross weight equal to or greater than the minimum weight (minimum of 20 divisions) and less than
the maximum capacity.
• Net weight not null. Between two successive requests, the weight must have a variation of 20 divi-
sions; if the weight is unstable the command is not executed.