dELAy2
SET-POINT 2 DELAY [1416]
Value of time, in tenths of a second, after which, when the set weight value is exceeded, the output
associated with set-point 2 is enabled.
The function is not active with programmed time equal to zero
Values: from 000 to 999
Default: 0