PRESET KEY
This key is used to enter the weight values for the three preset weight comparators or for the
checkweigher feature depending on which feature was selected (setup parameter
during setup and calibration.
Preset Weight Comparator
If the Preset Weight Comparator feature was selected in the
key pressed, the display will show
value for the number 1 preset weight comparator will be displayed. If the value displayed is
acceptable, press the ENTER key, otherwise, use the numeric keys to enter the new preset
value and press the ENTER key. The display will show
SETUP
selected in
. Press the ENTER key and the currently stored value for the number 2
preset weight comparator will be displayed. As before, if the value displayed is acceptable,
press the ENTER key, otherwise, use the numeric keys to enter the new value and press
the ENTER key. The display will show
Press the ENTER key and the currently stored value for the number 3 preset weight
comparator will be displayed. As before, if the value displayed is acceptable, press the
ENTER key, otherwise, use the numeric keys to enter the new value and press the ENTER
key.
Checkweigher (Can be used with 2XX-OU, Checkweigher Light Bar Option)
If the Checkweigher feature was selected and the PRESET key pressed, the display will
UNDER=
show
. Press the ENTER key and the currently stored value for the minimum
acceptable weight will be displayed. Press the ENTER key if the displayed value is correct
or use the numeric keys and enter the new value and press the ENTER key. The display will
OVER=
show
. Press the ENTER key and the currently stored value for the minimum
acceptable over weight will be displayed. As before, if the value shown is correct, press the
ENTER key. If the value is incorrect, enter the new value and press the ENTER key to save
it.
OVER=
Note: the
. value must be greater than the
Remember that both the preset weight comparators and checkweigher
functions operate on the absolute value of weight ignoring the polarity.
After the last preset value is entered, the indicator will return to normal
operation.
8200-M628-O1 Rev A  212G/212GX Installation & Technical
KEYPAD FUNCTIONS, CONT.
PSET1=
. Press the ENTER key and the currently stored
PSET3=
SETUP
menu, and the PRESET
PSET2=
if 2 or 3 active presets were
if 3 active presets were selected in
UNDER=
value.
D out
)