Additional Instructions For Installation Of Your Dryer In A Manufactured Or Mobile Home - Asko TL751 XXL Operating Instructions Manual

Asko tl751xxl:
Hide thumbs Also See for TL751 XXL:
Table of Contents

Advertisement

Installation instructions
Step 8. Additional instructions
for installation of your dryer in a
manufactured or mobile home
The following instructions are applicable to
installations of the dryer in a manufactured
or mobile home. Any installation in a
manufactured or mobile home must comply
with the Manufactured Home Construction
and Safety Standards Title 24 CFR, Part
32-80 or Standard CAN/CSA0Z240 MH
and local codes and ordinances. If you are
uncertain whether your proposed installation
will comply with these standards.
Please contact a service and installation
professional for assistance. (Customer Care
Center 1-800-898-1879 www.askousa.com)
The following instructions apply
to any installation of the dryer in a
manufactured or mobile home:
1.
The electrical connection for an electric
dryer must be a 4-wire connection.
More detailed information concerning
the electrical connection is provided at
the manual section entitled electrical
requirements for electric dryer
2.
To reduce the risk of combustion and fire,
the dryer must be vented to the outside.
3.
Electric dryers may be vented to the
outside using the back, left, right, or
bottom panel.
4.
Gas dryers may be vented to the outside
using the back, left, or bottom panel. Gas
dryer may not be vented to the outside
using the right side panel because of the
burner housing.
5.
The dryer exhaust duct must be affixed
securely to the manufactured or mobile
home structure, and the exhaust duct
must be made of a material that will
30
resist fire and combustion, and it is
recommended that you use a rigid or
flexible metal pipe.
6.
Do not connect the exhaust duct with any
other duct, vent, chimney, or other exhaust
duct.
7.
Make sure the dryer has adequate access
to outside fresh air to ensure proper
operation. The opening for outside fresh
air must be at least 25"
8.
It is important that the clearance of the
duct from any combustible construction
be at least 2 inches (5 cm), and, when
venting the dryer to the outdoors, the
dryer can be installed with a clearance of
1 inch at the sides and back of the dryer.
9.
Please be aware that venting materials
are not supplied with the dryer. You should
obtain the venting materials necessary for
proper installation.
Caution!
Do not connect exhaust ducts with
metal screws or fasteners that extend
into the duct.
Do not vent the exhaust duct under the
manufactured or mobile home.
Customer Care Center
1-800-898-1879
www.askousa.com