Electrical requirements
Option 1: 4-wire connection with a
power supply cord
lf your local codes or ordinances do not
allow the use of a 3-wire connection,
or you are installing your dryer in a
mobile home, you must use a 4-wire
connection.
38
1.
Connect neutral wire (white) of power cord
to center terminal block screw.
2.
Connect red and black wires to the left
and right terminal block screws.
3.
Connect ground wire (green) of power
cord to external ground screw and move
neutral ground wire of appliance and
connect it to center screw.
4.
Make sure that the strain relief screw is
tightened.
Be sure that all terminal block nuts are on
tight and power cord is in right position.