ColorSource CYC v1.7

Error Codes

There are three error codes that may be shown on the user interface.
CAL
the color calibration. The fixture will need to be returned to the ETC
factory; contact your local dealer to set up a repair.
OtP
has gone into over-temperature protection mode to avoid damaging
the fixture. Once the fixture has self-cooled, the error will automatically
clear.
No App
upgraded fixtures have a software issue. Reload software to clear the
error. If the error persists, contact ETC.

RDM Values

Parameter
Manufacturer ID
Model ID
DMX Start Address
DMX Personality
Output Frequency
ColorSource CYC
: Screen toggles between
: Screen toggles between
: Screen toggles between
Value
0x6574
0x0215
0x00F0
0x00E0
0x8123
CAL
ERR
and
to indicate a problem with
OtP
ERR
and
to indicate that the fixture
no
APP
and
Description
Electronic Theatre Controls
ColorSource CYC
Range = 1–512
1 = 5 Channel
2 = Direct
3 = 1 Channel
4 = RGB
0 = Standard (1.2 kHz)
1 = High (25 kHz)