Cascade regulator electrical connection.

main supply connection.
1 - Relay output (not used)
2 - Relay input (not used)
3 - Direct circuit pump (HC)
4 - N.C.
5 - Domestic hot water circuit pump
6 - L 1/ 230 V (main supply)
7 - Mixed circuit valve (MC 1) OPEN
8 - Mixed circuit valve (MC 1) CLOSED
9 - Mixed circuit 1 pump
10 - Variable output relay 1
11 - Variable output relay 2
12 - L 1 230/V
13 - Mixed circuit valve (MC 2) OPEN
14 - Mixed circuit valve (MC 2) CLOSED
15 - Mixed circuit 2 pump
16 - N.C.
17 - Relay output (not used)
18 - Relay input (not used)
19 - (not used)
20 - (not used)
21 - N/230V
22 - L1 /230V
Low tension connections.
23 - GND common
24 - Data bus connection - signal A (zone controls and
room thermostats)
Pic. 10
25 - Data bus connection - signal B (zone controls and
room thermostats)
26 - External sensor (not to use, connect to the boiler)
27 - (not to use)
28 - Domestic hot water sensor
29 - Temperature sensor zone 1
30 - Variable input 1
31 - Variable input 2
32 - Variable input 3
33 - Temperature sensor zone 2
34 - Solar panel sensor
35 - Solar storage tank sensor
36 - Impulses input
37 - Boiler data bus A
38 - Boiler data bus B
NOTE: For the connection to the hydraulic circuit
components see the schemes at pages 15-19.
Bus address (Cascade regulator).
In case that only one cascade regulator is in-
stalled, the bus address is always 10. With more
regulators connected (at least five) the regulator
directly connected to the boiler must have the bus
address 10. For the other regulators, the addresses
must follow numbers 20, 30, 40 e 50.