Immergas VICTRIX PRO 35 1 I Instructions And Warning Book For The Users
Immergas VICTRIX PRO 35 1 I Instructions And Warning Book For The Users

Immergas VICTRIX PRO 35 1 I Instructions And Warning Book For The Users

Cascade and zone regulator zone manager
Hide thumbs Also See for VICTRIX PRO 35 1 I:

Advertisement

IE
IE
Instructions and warning book
Instructions and warning book
for the users
for the user
Cascade and zone regulator
Zone manager
Thermoregulation for boilers

Advertisement

Table of Contents
loading

Summary of Contents for Immergas VICTRIX PRO 35 1 I

  • Page 1 Cascade and zone regulator Zone manager Thermoregulation for boilers Instructions and warning book Instructions and warning book for the user for the users...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction........................................... 4 Visualization and control elements........................................4 Operation................................................5 Keys function..............................................6 Temperature settings............................................6 Operational mode selection for heating and domestic hot water..............................7 Functions of operational modes........................................... 8 Setting the heating characteristics (heating curve)..................................9 System information.
  • Page 3 Error messages..........................................27 Special operating modes (for technician)..................................28 Emission measurement..........................................28 Manual mode (for technician)..................................... 29 Product specifications ........................................30...
  • Page 4: Introduction

    INTRODUCTION. Page 4 Visualization and control elements. Zone manager VICTRIX 50 Cascade and zones regulator VICTRIX 50 1 - Main knob with two functions (turn-push) 2 - Setting daytime temperature 3 - Setting reduced temperature 4 - Setting domestic hot water temperature 5 - Heating and set back programs 8 - Manual mode and emission measurement 6 - Setting heating parameters...
  • Page 5: Operation

    Operation. The center-positioned knob and the labelled keys makes the operation simple and easy to handle. - Each changeable value in the display appears flashing and can be modified with the knob. Turn to the right (+) clockwise: increase values. Symbols used in this manual: Turn to the left (-) anticlockwise: decrease values.
  • Page 6: Keys Function

    KEYS FUNCTION. Page 6 Temperature settings. This button is used to set the daytime room temperature . Required reduced Required daytime D. h. w. This button is used to set the required room temperature room temperature temperature reduced temperature. This button is used to set the required domestic hot water temperature.
  • Page 7: Operational Mode Selection For Heating And Domestic Hot Water

    Operational mode selection for heating and domestic hot water. With this button the required operational mode is selected. It appears in plain text on the display, simultaneously an arrow at the lower edge of the display points to the appartaining symbol. Select: Pressing the operational mode selection button, the previously set mode appears flashing.
  • Page 8: Functions Of Operational Modes

    Functions of operational modes. Page 8 Domestic hot water Permanent Plant off Plant off Interrupt heating Extend heating Heating operation Permanent heating red. heating operation frost protection only during holiday operation operation via timer operation holiday til- AbSENT til PARTY til wE.
  • Page 9: Setting The Heating Characteristics (Heating Curve)

    This button regulates the heating characteristics Setting the heating characteristics (heating curve). of each heating circuit in relation to outside temperature The adjustment is independent of the system and shows the relation between outside temperature and max. heating temperature. Direct heating Mixed heating Mixed heating The slope sets the change of the max.
  • Page 10: System Information

    System information. Page 10 Entry to information level The info button displays general information such as boiler water temperatures, and other conditions. outside 13.5 °C Turning the knob clockwise the display shows: Outside temperature - temperatures (real and setting values) Examples: Examples: - variable inputs (function and value)
  • Page 11 - functioning status when connecting a modem to AUTO - p1 day room TEMP. hc Room temperature a variable input Domestic hot water circuit Direct heating circuit 14.5 (if room probe activated) °C room TEMP. mc 1 heat. gener. Room temperature Boiler status Mixed heating circuit 1 ST - 1...
  • Page 12: Programming Of The Thermoregulation System

    PROGRAMMING OF THE THERMOREGULATION SYSTEM. Page 12 Programming of functioning parameters. su. 9.Aug. ‘01 Standard display Entry into the programming level is done by pushing the knob for approx. 3 seconds during the standard display. 58.5 °C 19:45 The main parameters are already factory setted, in case of modification operate as follow: Entry into the level selection press the knob for approx.
  • Page 13 Selection and modification of parameters and setting values. OPERATING MODE DAY- HEATING START Entering into the programming level, principally the OPERATING-TIMES common (1) MONTH selected cycle separate (2) level appears at first. All other levels, such as - SYSTEM back forward back forward...
  • Page 14: Programming Of Operating Times

    Programming of operating times. Page 14 With this operation mode, individual programs for heating and domestic hot water mode can be we. 21.AuG. ‘02 set up. After selecting the corresponding heating-d.h.w. circuit, the standard program (P1) is called Standard display 62.5 °C 15:30...
  • Page 15 06.00-22.00 --.-----.-- 06.00-22.00 --.-----.-- --.-----.-- day and - Wed- Thu- Fri- Sat- Sun- Select cycle 20.0 °C --.- °C 20.0 °C --.- °C --.- °C mo-1 mo-2 tu-1 tu-2 su-2 Example: tuesday - cycle 1 accept Note: The 3rd heating cycle is skipped if the 2nd heating cycle does not include any 06.00-22.00 operating times!
  • Page 16: Copying Operating Times

    Copying operating times. Page 16 we. 21 . AuG.’02 Standard display °C 62.5 15:30 This function allows to copy operating times of any day of the week to other days (Mo - Su) or to the whole week (1 - 7) or parts of a week such as workdays (1 - 5) or weekends (6 - 7).
  • Page 17 Setting range: copy Select source Monday (MO)...Sunday (SU) Modify - exit: from Example: Monday Confirm selected flashing value by pressing the knob. Then set the new required value accept via knob by pressing it again. Re-entry into the former step by pressing the button Setting range: , exit into the standard display via the copy...
  • Page 18: Return Loading Of Standard Programs: Deleting Of Individual Operating-Times Programs

    Return loading of standard programs: deleting of individual operating-times programs. Page 18 we 21 . AuG.’02 Standard display When doing this operation the operating times programs which were °C 62.5 15:30 changed will be definitely lost and replaced by the standard programs indicated in the tables below.
  • Page 19 select program if available Reset 3sec press approx. for 3 seconds RESET Note: The programs P2 e P3 appear only Standard program was reloaded if the option P1-P3 in the System Individual program was deleted! level is activated. Standard operating times programs are the following: Standard operating times program P1 Standard operating times program P2 Standard operating times program P3...
  • Page 20: Parameters Configuration

    PARAMETERS CONFIGURATION. Page 20 Setting of system parameters (for the technician). Entry: See “Programming of functioning SySTEM This level includes general delimiting parameters and options referring parameters” page 12-13. to the corresponding heating system. SyST. Exit: Button or automatically after 60 Entry: seconds Language choice...
  • Page 21 Control mode setting range: 1 = common mode 2 = separated mode control mode factory preset: 2 SyST. Common control mode: The selected operational mode via button (holiday, absent, party, auto, etc.) and the temperatures setted via button applies to all heating circuits together (MC 1, MC 2 and HC). next parameter Separated control mode: Each heating circuit can be assigned with its own operational mode and temperature settings.
  • Page 22 Summer switching-off. Page 22 summer setting range: OFF, 10.0 to 30,0 °C factory preset: 20.0 °C 20.0 °C SyST. This parameter specifies the heating delimiting value compared to current outside temperature and puts the heating system automa- next parameter tically out of service as soon as the outside temperature exceeds the set heating delimiting value.
  • Page 23: Domestic Hot Water Parameters Setting

    Domestic hot water parameters setting. Entry: see page 12-13. This level includes the necessary parameters for program- dhw. ming the hot water economic temperature and the legionella Exit without protection. modifications: via button or automatically after 60 sec. Entry: Hot water economic temperature. Setting range: 10.0 °C up to the required hot water temperature.
  • Page 24: Heating Circuits Parameters Setting (Direct Circuit, Mixed Circuit 1, Mixed Circuit 2) (For Technician)

    Heating circuits parameters setting (direct circuit, mixed circuit 1, mixed circuit 2) (for technician). Page 24 This level includes the parameters required for programming Entry: see page 12-13. unmixed circ. the reduced heating mode and the adaptation to the corre- sponding heating system.
  • Page 25 Adaptation to the heating system (value m). heat. system setting range: 1.00 to 10.0 factory preset: 1.30 1. 30 This parameter refers to the type of the heating system inside Applications: the heating circuit and has to be adapted to the exponents of the following setting values are recommended for the below- the corresponding consumer (underfloor-radiator-convector).
  • Page 26: Time - Date

    Page 26 Time - date. Entry: see page 12-13. time-DATe Entry : Exit: via button or automatically after 60 sec. Current time: time setting range: first parameter The beside standing values are factory preset and normally 18:45 0.00 ... 24.00 h need not be updated.
  • Page 27: Error Messages

    ERROR MESSAGES. The instrument is equipped with an extensive error diagnostic fea- Example for error messages “sensor” (short or open flow tures, The error displayed takes priority over other displays. circuit) 12-0 ERROR error code 10. ..20 with index 0 or 1 Note: error messages only appear alternating with the standard display.
  • Page 28: Special Operating Modes (For Technician)

    Page 28 SPECIAL OPERATING MODES (FOR TECHNICIAN). Button for the emissions measurement from Emission measurement. authorized personnel. When pressed, all circuits operate at their maximum preset temperature for 20 minutes. After this time the emission measurement can be activated again. The remaining time appears in the display during the whole measurement.
  • Page 29: Manual Mode (For Technician)

    MANUAL MODE (FOR TECHNICIAN). Continues heating and domestic hot water operation in case of malfunctioning. When the button is pressed for more than 5 seconds while showing the standard display, the control unit is switched over to manual mode. All control functions are released, the required boiler temperature can be adjusted by the knob.
  • Page 30: Product Specifications

    PRODUCT SPECIFICATIONS. Page 30 In accordance with Regulation 811/2013 the temperature control device class is: Contribution to the environmental Class Description heating seasonal energy efficiency Administrator kit VIII Administrator kit coupled to 3 environment sensors...

Table of Contents