ZONES mANAGER.

Installation place.

a - Use without ambient probe.
If the ambient probe is not activated, the
appliance can be installed everywhere.
b - Use with ambient probe.
If the room thermostat is activated, the
appliance must be located at a height of
1,20-1,50 m and in a suitable position for
correctly measuring the temperature. For
this purpose an intermediate wall of the
coldest zone can be chosen.
The appliance must not be installed:
- in places directly exposed to sunlight.
- in the vicinity of appliances that produce he-
ath such as TV sets, refrigerators, wall lamps,
radiators, etc.
- on walls behind which there are heating pipes
or flues.
- on not insulated external walls.
- in corners or recesses, on shelves, or behind
the curtains.
- near entrance doors of not heated rooms.
Pic. 5

Installation.

After opening the upper part, the wall support
can be fixed in the required place with the screws
and plugs supplied.
The data bus cable must pass through the lower
opening.
Recommended connection cable: J-Y(ST)Y 2
x 0.6
Max lenght: 50 m.