Solar Configuration Level - Immergas VICTRIX PRO 35 1 I Instruction For Technician And Installer

Thermoregulation system
Hide thumbs Also See for VICTRIX PRO 35 1 I:
Table of Contents

Advertisement

Solar configuration level (..vv..)
The parameters included in this section refer to the special adjustments for solar features. The enabling is possible only if the relative activation is present
into the hydraulic section.
PARAmETER
Description
01
Hysteresis ON
02
Hysteresis OFF
03
Min. run time solar pump
04
Solar collector max. temperature
05
Solar tank max. limit
06
Solar operational mode
07
Inhibition heat generation alternance (only with parameter 06=1)
08
Change priority/ parallel mode
09
Solar energy balance
SOLAR RESET
Reset energy balance
11
Volumetric flow rate
12
Density HTM
13
Heat capacity HTM
Regulation
Setting range / Parameters
10
(Hysteresis OFF +3 K) ... 30 K
5
2 K ... (Hysteresis ON - 3K)
3
0 ... 60 Min
120
70 ... 250 °C
75
20 ... 110 °C
1
1
Priority working
2
Parallel working
3
Piority for D.h.w
4
Piority for buffer
OFF
OFF, 0,5 ... 24 h
OFF
OFF, (only with par. 06=1 and par. 07=ON)
1 ... 30 K
OFF
OFF
No thermal balance
1
Thermal balance with flow rate calculation
2
Thermal balance through pulses inlet
RESET pressing the knob
0,0
0,0 ... 30 l/min o l/pulse (only for solar energy balance active)
1,05
0,8 ... 1,2 kg/l (only for solar energy balance active)
3,6
3,0 ... 5,0 kJ/kgK (only for solar energy balance active)
Page 35

Advertisement

Table of Contents
loading

Table of Contents