CASCADE AND ZONES REGU-
LATOR.

Cascade and zones regulator installation.

The cascade regulator is designed for flush-
mounted installation.
The fixing is done turning clockwise the two
lateral screws (1).
Turn anti-clockwise for disassembling.
Pic. 8

Electrical installation.

The electrical connection and wiring must be
done in the back side of the appliance as reported
in the following page scheme.
!
All the connection terminals inside the blue
area (X1) work with safety low voltage and they
have not to connect to the main supply voltage.
If this happens the appliance will destroy and
you will lose the warranty!
The connection terminals inside the red area (X2....
X4) work with the main supply voltage.
Warning:
- For the wiring of the appliance the bus data
and sensors cables must be layed separately
from electric wires. Sensor and bus data cables
cannot be layed together with electrical supply
wires of other electrical appliances.
Pic. 9
- For the connection it is necessary to use the
special screwing connector (X1÷X4) provi-
ded.
230 V ~