Adaptation to the heating system (value m).
heat. system
setting range: 1.00 to 10.0
factory preset: 1.30
1. 30
Hc
This parameter refers to the type of the heating system inside
the heating circuit and has to be adapted to the exponents of
the corresponding consumer (underfloor-radiator-convector).
The setting value specifies the curvature of the heating curve.
Applications:
the following setting values are recommended for the below-
mentioned applications:
Setting value
Application
Heating curve for underfloor heating systems
1.1
or other static heating surfaces
1.3
Normal standard heating curves for radiators
3.0. . . 4.0
Heating curve for convectors
Special heating curve for ventilators with high
4.0. . . 10.0
starting temperatures