Control mode
setting range: 1 = common mode 2 = separated mode
control mode
factory preset: 2
1
SyST.
Common control mode:
The selected operational mode via button
applies to all heating circuits together (MC 1, MC 2 and HC).
next parameter
Separated control mode:
Each heating circuit can be assigned with its own operational mode and temperature settings. With separated mode all regulations
refer also only to the previously selected heating circuit as shown below.
Select
heating circuit
Operational mode
OP. MODE.
Hc
HC, MC 1, MC 2, DHW
accept
continue as for common control mode
(holiday, absent, party, auto, etc.) and the temperatures setted via button
Daytime temperature
ROOM DAY
22. 0
°C
Mc1
HC, MC 1, MC 2
Set back temperature
ROOM NIGHT
17. 0
°C
Mc2
HC, MC 1, MC 2
and
Page 21