Parameter Name
Ethernet communica-
1425
tion station number
Link speed and duplex
1426
mode selection
Ethernet function
1427
selection 1
Ethernet function
1428
selection 2
Ethernet function
1429
selection 3
Ethernet signal loss
1431
detection function
selection
Ethernet communica-
1432
tion check time
interval
1434
Ethernet IP address 1
1435
Ethernet IP address 2
1436
Ethernet IP address 3
1437
Ethernet IP address 4
1438
Subnet mask 1
1439
Subnet mask 2
1440
Subnet mask 3
1441
Subnet mask 4
Ethernet IP filter
1442
address 1
Ethernet IP filter
1443
address 2
Ethernet IP filter
1444
address 3
Ethernet IP filter
1445
address 4
Ethernet IP filter
1446
address 2 range
specification
Ethernet IP filter
1447
address 3 range
specification
Ethernet IP filter
1448
address 4 range
specification
Ethernet command
1449
source selection IP
address 1
Ethernet command
1450
source selection IP
address 2
Ethernet command
1451
source selection IP
address 3
Ethernet command
1452
source selection IP
address 4
Setting Range
Initial Value
1 to 120
1
0
0 to 4
502,
5000 to 5002,
5006 to 5008,
5001
5010 to 5013,
9999, 45237,
61450
502,
5000 to 5002,
5006 to 5008,
45237
5010 to 5013,
9999, 45237,
61450
502,
5000 to 5002,
5006 to 5008,
9999
5010 to 5013,
9999, 45237,
61450
0
0 to 3
9999
0 to 999.8 s, 9999
192
0 to 255
168
0 to 255
50
0 to 255
1
0 to 255
255
0 to 255
255
0 to 255
255
0 to 255
0
0 to 255
0 to 255
0
0
0 to 255
0
0 to 255
0
0 to 255
9999
0 to 255, 9999
9999
0 to 255, 9999
9999
0 to 255, 9999
0
0 to 255
0
0 to 255
0
0 to 255
0
0 to 255
Parameter Name
Ethernet command
source selection IP
1453
address 3 range
specification
Ethernet command
source selection IP
1454
address 4 range
specification
1455
Keepalive time
PID multistage set
1460
point 1
PID multistage set
1461
point 2
PID multistage set
1462
point 3
PID multistage set
1463
point 4
PID multistage set
1464
point 5
PID multistage set
1465
point 6
PID multistage set
1466
point 7
Number of cleaning
1469
times monitor
Number of cleaning
1470
times setting
Cleaning trigger
1471
selection
Cleaning reverse
1472
rotation frequency
Cleaning reverse
1473
rotation operation
time
Cleaning forward
1474
rotation frequency
Cleaning forward
1475
rotation operation
time
1476
Cleaning stop time
Cleaning acceleration
1477
time
Cleaning deceleration
1478
time
1479
Cleaning time trigger
Load characteristics
1480
measurement mode
Load characteristics
1481
load reference 1
Load characteristics
1482
load reference 2
Load characteristics
1483
load reference 3
Load characteristics
1484
load reference 4
Load characteristics
1485
load reference 5
Load characteristics
1486
maximum frequency
Load characteristics
1487
minimum frequency
Upper limit warning
1488
detection width
BASIC OPERATION
Setting Range
Initial Value
9999
0 to 255, 9999
9999
0 to 255, 9999
3600 s
1 to 7200 s
9999
9999
9999
9999
0 to 100%, 9999
9999
9999
9999
0
0 to 255
0
0 to 255
0
0 to 15
30 Hz
0 to 590 Hz
0 to 3600 s
5 s
9999
0 to 590 Hz, 9999
9999
0 to 3600 s, 9999
5 s
0 to 3600 s
9999
0 to 3600 s, 9999
9999
0 to 3600 s, 9999
0 to 6000 h
0 h
0, 1,
0
(2 to 5, 81 to 85)
0 to 400%, 8888,
9999
9999
0 to 400%, 8888,
9999
9999
0 to 400%, 8888,
9999
9999
0 to 400%, 8888,
9999
9999
0 to 400%, 8888,
9999
9999
50 Hz
0 to 590 Hz
6 Hz
0 to 590 Hz
20%
0 to 400%, 9999