Parameter Name
453
Second motor capacity
Number of second
454
motor poles
Second motor
455
excitation current
Rated second motor
456
voltage
Rated second motor
457
frequency
Second motor
458
constant (R1)
Second motor
459
constant (R2)
Second motor
460
constant(L1)/
d-axis inductance (Ld)
Second motor
461
constant (L2)/
q-axis inductance (Lq)
Second motor
462
constant (X)
Second motor auto
463
tuning setting/status
Remote output
495
selection
496
Remote output data 1
497
Remote output data 2
PLC function flash
498
memory clear
Stop mode selection at
502
communication error
503
Maintenance timer 1
Maintenance timer 1
504
warning output set
time
Speed setting
505
reference
Display estimated
506
main circuit capacitor
residual life
Emergency drive
514
dedicated retry
waiting time
Emergency drive
515
dedicated retry count
522
Output stop frequency
Emergency drive
523
mode selection
*2
For FR-F846-01160(55K) or lower
*3
For FR-F846-01800(75K) or higher
Setting Range
Initial Value
0.4 to 55 kW,
*2
9999
9999
0 to 3600 kW,
*3
9999
2, 4, 6, 8, 10, 12,
9999
9999
0 to 500 A,
*2
9999
9999
0 to 3600 A,
*3
9999
400 V
0 to 1000 V
10 to 400 Hz,
9999
9999
0 to 50 Ω,
*2
9999
9999
0 to 400 mΩ,
*3
9999
0 to 50 Ω,
*2
9999
9999
0 to 400 mΩ,
*3
9999
0 to 6000 mH,
*2
9999
9999
0 to 400 mH,
*3
9999
0 to 6000 mH,
*2
9999
9999
0 to 400 mH,
*3
9999
9999
0 to 100%, 9999
0, 1, 11, 101
0
0
0, 1, 10, 11
0
0 to 4095
0
0 to 4095
0, 9696
0
(0 to 9999)
0
0 to 4
0
0 (1 to 9998)
9999
0 to 9998, 9999
50 Hz
1 to 590 Hz
100%
0 to 100%
0.1 to 600 s, 9999
9999
1
1 to 200, 9999
9999
0 to 590 Hz, 9999
100, 111, 112,
121 to 124, 200,
211, 212,
221 to 224, 300,
9999
311, 312,
321 to 324, 400,
411, 412,
421 to 424, 9999
Parameter Name
Emergency drive
524
running speed
Frequency command
541
sign selection
CC-Link extended
544
setting
USB communication
547
station number
USB communication
548
check time interval
NET mode operation
550
command source
selection
PU mode operation
551
command source
selection
552
Frequency jump range
553
PID deviation limit
PID signal operation
554
selection
555
Current average time
556
Data output mask time
Current average value
557
monitor signal output
reference current
Second frequency
560
search gain
PTC thermistor
561
protection level
Energization time
563
carrying-over times
Operating time
564
carrying-over times
Second motor
565
excitation current
break point
Second motor
566
excitation current low-
speed scaling factor
Second motor speed
569
control gain
571
Holding time at a start
4 mA input check
573
selection
Second motor online
574
auto tuning
Output interruption
575
detection time
Output interruption
576
detection level
Output interruption
577
cancel level
Auxiliary motor
578
operation selection
Motor connection
579
function selection
MC switching interlock
580
time (multi-pump)
Start waiting time
581
(multi-pump)
BASIC OPERATION
Setting Range
Initial Value
0 to 590 Hz, 9999
9999
0
0, 1
0, 1, 12, 14, 18, 24,
0
28, 100, 112, 114,
118, 128
0
0 to 31
0 to 999.8 s, 9999
9999
9999
0, 1, 5, 9999
9999
1 to 3, 5, 9999
9999
0 to 30 Hz, 9999
9999
0 to 100%, 9999
0
0 to 7, 10 to 17
1 s
0.1 to 1 s
0 s
0 to 20 s
*2
Inverter
0 to 500 A
rated
*3
0 to 3600 A
current
9999
0 to 32767, 9999
Ω
0.5 to 30 k
,
9999
9999
0
(0 to 65535)
0
(0 to 65535)
9999
0 to 400 Hz, 9999
9999
0 to 300%
9999
0 to 200%, 9999
9999
0 to 10 s, 9999
9999
1 to 4, 9999
0
0, 1
1 s
0 to 3600 s, 9999
0 to 590 Hz
0 Hz
1000%
900 to 1100%
0
0 to 3
0 to 3
0
1 s
0 to 100 s
1 s
0 to 100 s
25