Download Print this page

Mitsubishi Electric 800 Series Installation Manualline page 32

Inverter for fans and pumps
Hide thumbs Also See for 800 Series:

Advertisement

BASIC OPERATION
Parameter Name
Auxiliary motor
582
connection-time
deceleration time
Auxiliary motor
583
disconnection-time
acceleration time
Auxiliary motor 1
584
starting frequency
Auxiliary motor 2
585
starting frequency
Auxiliary motor 3
586
starting frequency
Auxiliary motor 1
587
stopping frequency
Auxiliary motor 2
588
stopping frequency
Auxiliary motor 3
589
stopping frequency
Auxiliary motor start
590
detection time
Auxiliary motor stop
591
detection time
Traverse function
592
selection
Maximum amplitude
593
amount
Amplitude
594
compensation amount
during deceleration
Amplitude
595
compensation amount
during acceleration
Amplitude
596
acceleration time
Amplitude
597
deceleration time
598
Undervoltage level
X10 terminal input
599
selection
First free thermal
600
reduction frequency 1
First free thermal
601
reduction ratio 1
First free thermal
602
reduction frequency 2
First free thermal
603
reduction ratio 2
First free thermal
604
reduction frequency 3
Power failure stop
606
external signal input
selection
Motor permissible load
607
level
Second motor
608
permissible load level
PID set point/
609
deviation input
selection
PID measured value
610
input selection
Acceleration time at a
611
restart
26
Setting Range
Initial Value
1 s
0 to 3600 s, 9999
1 s
0 to 3600 s, 9999
50 Hz
0 to 590 Hz
0 to 590 Hz
50 Hz
50 Hz
0 to 590 Hz
0 Hz
0 to 590 Hz
0 to 590 Hz
0 Hz
0 Hz
0 to 590 Hz
5 s
0 to 3600 s
0 to 3600 s
5 s
0
0 to 2
10%
0 to 25%
10%
0 to 50%
10%
0 to 50%
5 s
0.1 to 3600 s
5 s
0.1 to 3600 s
350 to 430 V DC,
9999
9999
0
0, 1
0 to 590 Hz, 9999
9999
100%
1 to 100%
9999
0 to 590 Hz, 9999
1 to 100%
100%
9999
0 to 590 Hz, 9999
1
0, 1
150%
110 to 250%
110 to 250%,
9999
9999
2
1 to 5
1 to 5,
3
101 to 105
0 to 3600s,
9999
9999
Parameter Name
Reverse rotation
617
excitation current low-
speed scaling factor
Speed smoothing
653
control
Speed smoothing
654
cutoff frequency
Analog remote output
655
selection
Analog remote output
656
1
Analog remote output
657
2
Analog remote output
658
3
Analog remote output
659
4
Increased magnetic
excitation
660
deceleration
operation selection
Magnetic excitation
661
increase rate
Increased magnetic
662
excitation current
level
Control circuit
663
temperature signal
output level
Regeneration
665
avoidance frequency
gain
Power failure stop
668
frequency gain
SF-PR slip amount
673
adjustment operation
selection
SF-PR slip amount
674
adjustment gain
User parameter auto
675
storage function
selection
Tuning data unit
684
switchover
686
Maintenance timer 2
Maintenance timer 2
687
warning output set
time
688
Maintenance timer 3
Maintenance timer 3
689
warning output set
time
Second free thermal
692
reduction frequency 1
Second free thermal
693
reduction ratio 1
Second free thermal
694
reduction frequency 2
Second free thermal
695
reduction ratio 2
Second free thermal
696
reduction frequency 3
699
Input terminal filter
Maximum motor
702
frequency
Setting Range
Initial Value
9999
0 to 300%, 9999
0%
0 to 200%
20 Hz
0 to 120 Hz
0
0, 1, 10, 11
1000%
800 to 1200%
1000%
800 to 1200%
1000%
800 to 1200%
1000%
800 to 1200%
0
0, 1
9999
0 to 40%, 9999
100%
0 to 300%
0 °C
0 to 100 °C
100%
0 to 200%
100%
0 to 200%
9999
2 to 4, 6, 9999
100%
0 to 500%
1, 9999
9999
0
0, 1
0
0 (1 to 9998)
9999
0 to 9998, 9999
0
0 (1 to 9998)
0 to 9998, 9999
9999
9999
0 to 590 Hz, 9999
1 to 100%
100%
9999
0 to 590 Hz, 9999
100%
1 to 100%
0 to 590 Hz, 9999
9999
9999
5 to 50 ms, 9999
9999
0 to 400 Hz, 9999

Advertisement

loading

This manual is also suitable for:

Fr-f846 e2-l2 seriesFr-f800-e