Climatic Zones And Performance Data; Performance Data - Beko BEKOMAT 13 Original Installation And Operation Manual

Table of Contents

Advertisement

BEKOMAT
®
13, 13 CO, 13 CO PN25, 13 CO PN40

4.4 Climatic zones and performance data

Depending on which climatic zone the product is used in, the product performance differs depending on the climatic
ambient conditions.
Climatic zone
Unit
m³/min.
green
blue
red
The performance data given refer to a moderate climate valid for Europe, large parts of South-East Asia, North and South
Africa, parts of North and South America (climatic zone: blue).
For a dry and / or cool climate (climatic zone: green), the following factor applies:
Performance in climatic zone "blue" x approx. 1.2
For a hot and / or humid climate (tropics, climatic zone: red), the following factor applies:
Performance in climatic zone "blue" x approx. 0.7

4.4.1 Performance data

BEKOMAT
®
Max. compressor
performance
Max. refrigeration dryer
performance
Max. filter performance
Operating pressure
Ø discharge rate
Max. discharge rate (short-
term)*
* The peak volume can only be achieved if the device is correctly installed according to the installation and operation
manual. If in doubt, a venting line must be installed.
16 | 64
Max. compressor
performance
cfm
35
1235
30
1060
20
705
13
1 bar(g)
2 bar(g)
14.5 psi(g)
29.01 psi(g)
3.17 l/h
4.12 l/h
0.83 gal/h
1.08 gal/h
50 l/h
60 l/h
13.20 gal/h
15.85 gal/h
Original installation and operation manual
Max. dryer performance
m³/min.
cfm
70
2470
60
2120
40
1412
13 CO
13 CO PN25
30 m³/min
1060 cfm
60 m³/min
2120 cfm
300 m³/min
10595 cfm
3 bar(g)
4 bar(g)
43.51 psi(g)
58.02 psi(g)
5.0 l/h
5.7 l/h
1.32 gal/h
1.50 gal/h
80 l/h
90 l/h
21.13 gal/h
23.77 gal/h
Max. filter performance
m³/min.
cfm
350
12360
300
10595
200
7063
13 CO PN40
5 bar(g)
≥ 6 bar(g)
72.52 psi(g)
87.02 psi(g)
6.35 l/h
7.61 l/h
1.67 gal/h
2.01 gal/h
100 l/h
120 l/h
26.41 gal/h
31.70 gal/h

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents