Installation Dimensions; Terminal Diagrams; Power Control Board; Control Pcb - Beko BEKOMAT 13 Original Installation And Operation Manual

Table of Contents

Advertisement

BEKOMAT
®
13, 13 CO, 13 CO PN25, 13 CO PN40

4.6 Installation dimensions

G1/2
(1/2" NPT)
G1/2
(1/2" NPT)

4.7 Terminal diagrams

4.7.1 Power control board

Illustration VAC board

4.7.2 Control PCB

18 | 64
Illustration
G1/2
BM 13, BM 13 CO
G3/8
BM 13 CO PN25 / 40
Normally Open (NO)
Common (CO)
Normally Closed (NC)
Protective earth conductor (PE)
PE
N
Neutral conductor (N)
L
Phase (L)
Illustration
Original installation and operation manual
Description / explanation
At the place of installation, allow sufficient
assembly space above the top cover so that the
LEDs are visible and the TEST button can be
pressed.
Illustration VDC board
Voltage supply
1.0
+24V
from the power control
1.1
0V
board
2.0
OT1
not assigned
2.1
2.2
INP1
External test button
2.3
0V
3.0
0V
+24V
3.1
Solenoid valve
3.2
OT2
Normally Open (NO)
Common (CO)
Normally Closed (NC)
24V+
24V-

Hide quick links: