Do you have a question about the BEKOMAT 13 and is the answer not in the manual?

Questions and answers

Blessing
April 24, 2025

What causes the valve to remain open always

2 comments:
Mr. Anderson
May 12, 2025

The valve in the Beko BEKOMAT 13 may remain open if the device keeps blowing off air. Possible causes include:

- Blocked control air line
- Worn parts
- Dirty sensor tube
- Incorrect or defective power supply
- Faulty control board

These issues prevent proper valve closing, causing it to stay open.

This answer is automatically generated

Blessing Martin
May 12, 2025

@Mr. Anderson thanks a million . At my case it was the relay fault on the control board.

Moses
May 12, 2025

What happens when the drain valve of bekomat constantly open discharging compressed air continuously

1 comments:
Mr. Anderson
May 20, 2025

A constantly open drain valve on a Beko BEKOMAT 13 causes continuous discharge of compressed air. This may result from blocked control air lines or worn parts, and leads to unnecessary air loss.

This answer is automatically generated

Summary of Contents for Beko BEKOMAT 13

  • Page 1 EN - english ES - español FR - français PT - português Instructions for installation and operation Instruciones de instalación y de servicio Instructions de montage et de service Instruções de instalação e de serviço Condensate drain / Purgador de condensados / Purgeur de condensat / Condutor de descarga de condensado BEKOMAT ®...
  • Page 2 BEKOMAT 13 CO PN50 2000366 Functional test of BEKOMAT device: • Briefly press test button 2 sec. • Valve opens for condensate discharge. Checking of alarm signal: • Shut off condensate inflow. • Press test button for at least 1 minute. • Red LED flashes (after 1 minute). • Alarm signal is being relayed. BEKOMAT 13, 13 CO, 13 CO PN25, 13 CO PN50...