Beko BEKOMAT 13 Original Installation And Operation Manual page 27

Table of Contents

Advertisement

Original installation and operation manual
Illustration
61
60 mm (2.36")
50 mm (1.96")
2
9
36
6 mm (0.23")
1 N/-
2 L/+
PE
5
6
7
I
Normally Open (NO)
Common (CO)
Normally Closed (NC)
PE
Schutzleiter (PE)
N
Neutralleiter (N)
L
Phase (L)
BEKOMAT
13, 13 CO, 13 CO PN25, 13 CO PN40
®
Description / explanation
5. Raise the top cover [2] a little and pull the screw
terminal [61] of the power control board up and off.
6. Unscrew the pan-head screw [36] and take the power
control board [9] out of the top cover [2].
7. Prepare the 3-wire cable of the voltage supply.
8. Slide the components of the cable gland [5, 6, 7] over
the cable for voltage supply [I] and insert the cable
into the top cover.
9. Connect the voltage supply cable to the power control
board in accordance with the terminal diagram.