Technical Data; Environmental Conditions - Beko DRYPOINT ACC 46 Instruction Manual

Table of Contents

Advertisement

Section 3: Technical Data

Technical Data

Environmental Conditions

All dryers are designed to be safe under the following conditions:
• Indoor use
• Altitude up to 6560 ft.
• Ambient temperature 41°F (5°C ) to 122°F (50°C)
• Mains supply voltage fluctuations not to exceed +/- 10% of nominal
For operation extended from the above conditions, please contact the manufacturer.
Excessive vibrations from external sources may cause failure
of this product.
Rated Conditions
Measurement
Inlet pressure
Inlet temperature
Relative humidity of air at inlet
Pressure dewpoint, standard version
Specified Limitation for Operation
Measurement
Maximum inlet air pressure
Minimum inlet air pressure
Maximum ambient air temperature
Minimum ambient air temperature
Pressure dewpoint*
Electrical supply voltage
* Pressure dewpoint dependant upon dryer sizing (see page 12). High performance cartridges required for -100°F (-74°C) operation.
10
Performance
100 psig
95°F
95%
-40°F
Performance
188.5 psig
58 psig
122°F
41°F
-4°F to -100°F
115 - 240 VAC 50-60 Hz or 24 VDC
Heatless Desiccant Dryers |
7 barg
35°C
-40°C
13 barg
4 barg
50°C
5°C
-20°C to -74°C
Instruction Manual

Advertisement

Table of Contents
loading

Table of Contents