Discharge Head
- 81 feet (25m)
Maximum
Prime the Water Pump
1. Remove priming plug from top of pump.
2. Fill pump with clean, clear water up to top of discharge
outlet.
3. Replace priming plug.
NOTICE
Improper treatment of water pump can damage it and
shorten its life.
• Be sure pump chamber is filled with water before starting the
engine. NEVER run pump without priming.
12
Total Head
- 106 feet (32m)
Maximum
Suction Head
- 25 feet (8m)
Maximum
Locate Strainer Basket Into Water Source
Place strainer basket into water to be pumped. Basket must
be fully immersed in water.
NOTICE
Improper treatment of water pump can damage it and
shorten its life.
• NEVER operate pump without strainer connected to end of
suction hose.
• Keep strainer out of sand or silt, place in bucket or on stones.
• DO NOT let pump run dry or damage to seals may result.
BRIGGSandSTRATTON.COM