damaged parts. Replace parts as needed.
ATTENTION
Before any disassembly and/or cleaning
procedure make sure that the dispenser is
disconnected from its power source by
unplugging it.
2
Every month: check that the hexagonal joint
gasket is not worn. If it is, replace the joint itself
with an original spare part from the manufacturer
(see figure 22).
figure 22
3
In case of noise it needs to unplug the cooler
and call for service.
4
In case of failure unplug the machine,
because unexpected start again would be
possible.
5
It needs to fix everything back in the initial
position after any repairmen, like screws and
covers.
8. 1 MAINTENANCE (TO BE
CARRIED OUT BY QUALIFIED
SERVICE PERSONNEL ONLY)
1
Annually: remove the panels and clean the
inside of the machine including the base, side
panels, condenser, etc.
2
Annually: Check if the auger bushings are
worn out or ovalized. If they are, replace them
with new ones.
3
In order to prevent any damages to the
dispenser, all plastics parts must be lubricated
only with grease supplied by the manufacturer or
with another lubricating product suitable for
polycarbonate.
23