Maintenance (To Be Carried Out By Qualified Service Personnel Only) - Bras B-Cube Operator's Manual

Hide thumbs Also See for B-Cube:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
original spare parts from the manufacturer.
ATTENTION
Condenser
fins
are
extreme caution when cleaning.
2
Every month: check that the hexagonal joint
gasket is not worn. If it is, replace the joint itself
with an original spare part from the manufacturer
(see figure 18).
figure 18
3
In the event of strange noises, disconnect
the cooler and call for assistance.
4
In the event of a breakdown, disconnect the
machine as it may start again suddenly.
5
After all repair work, reposition every
component, such as the screws and covers, in
their original position.
6
Once a month: eliminate any dust that has
built up on the condenser filter situated at the
very
sharp.
Use
rear of the machine (see figure 19).
8. 1 MAINTENANCE (TO BE
CARRIED OUT BY QUALIFIED
SERVICE PERSONNEL ONLY)
1
Once a month: eliminate any dust that has
built up on the condenser. Unplug the dispenser
beforehand.
2
Once a year: it is advisable to remove all the
panels and clean inside, including the base and
the internal parts of the panels.
3
Once a year: Check that the bushes on
which the mixers turn are perfectly round and not
worn. Replace them if necessary.
4
Never remove the anti-condensation material
around the outlet pipe of the evaporator (the
copper pipe to the right of the geared motor. If
this material is missing or worn out, replace it
w i t h o r i g i n a l s p a r e m a t e r i a l f r o m t h e
manufacturer.
5
In order to avoid damaging the dispenser,
lubricate the plastic parts only with the grease
provided by the manufacturer or with another
grease compatible with polycarbonate.
23
figure 19

Advertisement

Table of Contents
loading

This manual is also suitable for:

B-cube 1B-cube 2B-cube 3

Table of Contents