In-Place Sanitization; Routine Maintenance - Bras B-Cube HOT Operator's Manual

Table of Contents

Advertisement

Available languages

Available languages

EN GLIS H
B-Cube HOT
end (see figure 19).
figure 19
6
Install the outer spiral. Slide it over the
evaporator until its hexagonal front notch
engages with the hexagonal exposed end of the
magnetic outside rotor (see figure 20).
figure 20
7
Push the bowl towards the rear wall of the
unit until it fits snugly around the gasket and its
front fastening hooks are properly engaged (see
figure 21).
8
Use fresh product to chase any remaining
sanitizer from the bottom of the bowl(s). Drain
this solution. Do not rinse out the machine.

7. 6 IN-PLACE SANITIZATION

The In-Place Sanitization prior to starting the
machine may be performed, if needed, only as
f u r t h e r p r e c a u t i o n , i n a d d i t i o n t o t h e
Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare two gallons of a warm (45-60°C,
120-140 °F) sanitizing solution (100 PPM
available chlorine concentration or 1 spoon of
sodium hypoclorite diluted with 2 liters of water)
according to your local Health Codes and
manufacturer's specifications.
2
Pour the solution into the bowl(s).
3
Using a brush suitable for the purpose, wipe
the solution on all surfaces protruding above the
solution-level and on the underside of the top
cover(s).
4
Install the top cover(s) and operate the unit.
Allow the solution to agitate for about two
minutes. Drain the solution out of the bowl(s).
5
Use fresh product to chase any remaining
sanitizer from the bottom of the bowl(s). Drain
this solution. Do not rinse out the machine.

8 ROUTINE MAINTENANCE

1
Daily: inspect the machine for signs of
product leaks past seals and gaskets. If proper
assembly does not stop leaks around seals or
gaskets, check for improper lubrication, worn or
22