Rs232 Interface (Ttl) - Feig Electronic OBID i-scan ID ISC.M02 Installation Manual

Hide thumbs Also See for OBID i-scan ID ISC.M02:
Table of Contents

Advertisement

®
OBID i-scan
HF

3.2.2 RS232 interface (TTL)

The length of the cable to the RS232 interface should be kept as short as possible, and must in
any case not exceed 3 m.
Pin no.
*
**
The transmission parameters for the interface can be software-configured. Table 4 shows the
standard parameters for the RS232 interface.
Note:
If there is an USB/RS232 converter used on the PC/Notebook side, we recommend to
increase the „Char Timeout Multiplier" parameter in the COM-Port settings from „1" to
about „5".
IF there is a RS232 to TTL converter used without external power supply it may be nec-
essary to switch on the COM Port parameter "RTS" and "DTR" manually.
FEIG ELECTRONIC GmbH
X1
Function
3
TxD *
4, 9
GND **
5
RxD *
Signal names as seen by the Reader Module.
GND-Pins 4 and 9 are to be connected directly to each
other on the Reader Module
Table 3
: Pin assignments for the RS232 interface on X1
Parameter
Baud rate
No. of data bits
Parity
No. of stop bits
Table 4
: Standard parameters of the RS232 interface.
Installation
Description
ID ISC.M02-B
RS232-TTL - Transmit Data
GND
RS232-TTL - Receive Data
Standard setting
38400
8
Even
1
Page 11 of 27