Wiring - Feig Electronic OBID i-scan ID ISC.M02 Installation Manual

Hide thumbs Also See for OBID i-scan ID ISC.M02:
Table of Contents

Advertisement

®
OBID i-scan
HF

3.2 Wiring

Fig. 2 and Table 1 show the pin assignments for Terminal X1. The pin connector is designed for
flat cable connection using an IDC multipoint socket connector with 2.54 mm pin spacing.
X1
10
8
6
4
2
X1
Pin no.
1
2
3
4
5
6
7
8
9
10
*
**
FEIG ELECTRONIC GmbH
9
7
5
3
1
Fig. 2
: Pin assignments for Terminal X1
Function
DAT
CLK
TxD
GND **
RxD
---
CLS
VCC
GND **
---
Use only regulated DC power supplies !
GND-Pins 4 and 9 are to be connected directly to each other
on the Reader Module
Table 1
: Pin assignments for Terminal X1
Installation
V1
V2
X1
J1
X3
Description
ID ISC.M02-B
Data line for the data/clock interface
Clock line for the data/clock interface
RS232-TTL – Transmit Data
GND
RS232-TTL – Receive Data
not connected
CLS line for the data/clock interface
+ 5 V DC *
GND
not connected
Page 9 of 27
X4
C73
J2
X2
J3
C65
M20301-4e-ID-B.doc
ID ISC.M02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Obid i-scan id isc.m02 -b

Table of Contents