Feig Electronic ID ISC.LRM1002-E Integration Manual

Feig Electronic ID ISC.LRM1002-E Integration Manual

Long range reader module

Advertisement

INTEGRATION
ID ISC.LRM1002-E
Long Range Reader Modul
(English)
final – public (B)
2019-06-05 – M21110-3e-ID-B.docx

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic ID ISC.LRM1002-E

  • Page 1 INTEGRATION ID ISC.LRM1002-E Long Range Reader Modul (English) final – public (B) 2019-06-05 – M21110-3e-ID-B.docx...
  • Page 2 FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu- ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
  • Page 3: Table Of Contents

    LEDs .......................... 18 Radio Approvals Europe (CE) ....................... 19 USA (FCC) and Canada (IC) ..................20 5.2.1 Label Information Reader Modul ID ISC.LRM1002-E ..........21 5.2.2 USA (FCC) and Canada (IC) approved antennas ........... 21 Technical Data FEIG ELECTRONIC GmbH Page 3 from 23 M21110-3e-ID-B.docx...
  • Page 4: Safety Instructions / Warning - Read Before Start-Up

    Identification Integration Manual ID ISC.LRM1002-E Safety Instructions / Warning - Read before start-up !  The device may only be used for the purpose intended by the manufacturer.  The operation manual should be kept readily available at all times for each user.
  • Page 5: Performance Features Of Reader Family Id Isc.lrm1002

    Identification Integration Manual ID ISC.LRM1002-E Performance Features of Reader Family ID ISC.LRM1002 2.1 Performance Features The Reader has been developed for reading passive data carriers, so-called „Smart Labels“, using an operating frequency of 13.56 MHz. For the operation it is necessary to connect a appropriate external antenna to the connector ANT1.
  • Page 6: Installation And Mounting

    ø 4,5 mm IN + IN - ANT1 V3 V2 V1 ø 4,5 mm* ø 4,5 mm* ø 4,5 mm* Figure 1: Scale drawing oft the Reader module ID ISC.LRM1002-E with mounting plate FEIG ELECTRONIC GmbH Page 6 from 23 M21110-3e-ID-B.docx...
  • Page 7: Terminals

    If the antenna is properly tuned and there is sufficient air convection along the mounting plate, the ID ISC.LRM1002-E can be operated without an additional heat sink at up to 2W of power. Note here however that detuning of the antenna can result in additional heating of the Reader. In such cases the Reader regulates its output power down until the upper temperature limit of its final stage fallen down again.
  • Page 8: Antenna Connection

    Identification Integration Manual ID ISC.LRM1002-E 3.2.1 Antenna connection The SMA socket „ANT1“ is located on the circuit board for connecting the antenna to the ID ISC.LRM1002. A external LED can also be supplied with 6,5 V through the antenna terminal.
  • Page 9: Connection Of A Id Isc.dat (Dynamic Antenna Tuning Board)

    Identification Integration Manual ID ISC.LRM1002-E 3.2.1.1 Connection of a ID ISC.DAT (Dynamic Antenna Tuning Board) For tuning a ID ISC.DAT tuning board a DC voltage is required. This DC voltage must be provided via a power splitter (ID ISC.ANT.PS-B) or a antenna multiplexer (ID ISC.ANT.MUX) Figure 4 shows the DC supply of the ID ISC.DAT with a power splitter.
  • Page 10: Supply Voltage

    Identification Integration Manual ID ISC.LRM1002-E 3.2.2 Supply voltage The reader has to supplied by a limited power supply (e.g. NEC Class 2/LPS power supply) ac- cording IEC EN 60950, only. The supply voltage of 24 V is connected to Terminal X1.
  • Page 11: Optocouplerinputs (X5 / In1)

    Identification Integration Manual ID ISC.LRM1002-E 3.2.3 OptocouplerInputs (X5 / IN1) The optocoupler input is available on Terminal X5. IN + IN - Figure 7: Optocoupler pin-outs on terminal X5 The optocoupler on terminal strips X5 is galvanically isolated from the Reader electronics and must therefore be powered externally.
  • Page 12 Identification Integration Manual ID ISC.LRM1002-E Figure 9: Possible internal power supply for the optocouplers The input LED for the optocoupler is internally connected to a series resistor of 3,74k and is limited to an input current of max. 6mA. Note: ...
  • Page 13: Relay (X6 / Rel1)

    Identification Integration Manual ID ISC.LRM1002-E 3.3 Relay (X6 / REL1) The relay output has a changeover contact. These outputs, which are located on terminals X6, is galvanically isolated from the Reader electronics and must therefore be externally supplied. The external voltage may however be provided by the reader from connector X5 V and GND.
  • Page 14: Output 24V (X5 / Vin, Gnd)

    Identification Integration Manual ID ISC.LRM1002-E 3.3.1 Output 24V (X5 / V , GND) The output V /GND can be used to power the optional external circuitry of the digital inputs or relay. The maximum current consumption must not exceed 1A.
  • Page 15: Interfaces

    Identification Integration Manual ID ISC.LRM1002-E 3.4 Interfaces 3.4.1 RS232-Interface X4 The RS232 interface is connected on X4. The transmission parameters can be configured by means of software protocol. Figure 13: RS232 interface pin-outs on X4 Kurzzeichen Description RS232 – (Transmit) RS232 –...
  • Page 16: Usb - Interface X11 (Host Communication)

    Identification Integration Manual ID ISC.LRM1002-E 3.4.2 USB – Interface X11 (Host Communication) The USB socket on the board is terminal X11. The data rate is reduced to 12 Mbit (USB full speed). A standard USB-cable can be used. Figure 15: USB-Interface for host communication The Figure 16 and table shows the connection of connector X11 (5pol.) type “JST PH”...
  • Page 17: Ethernet-Interface On X3 (10/100 Base-T)

    Identification Integration Manual ID ISC.LRM1002-E 3.4.3 Ethernet-Interface on X3 (10/100 Base-T) The Reader has an integrated 10 / 100 Base-T network port for an RJ-45. Connection is made on X3 and has an automatic “Crossover Detection” according to the 1000 Base-T Standard.
  • Page 18: Operating And Display Elements

    Identification Integration Manual ID ISC.LRM1002-E Operating and Display Elements 4.1 LEDs Table 6 shows the LED configuration. Abbreviation Description LED V1 (green) "RUN-LED 1" Indicates proper running of the internal Reader software (DSP) Comes on during Reader initialization after power-on or after a reset.
  • Page 19: Radio Approvals

    ID ISC.LRM1002-E Radio Approvals 5.1 Europe (CE) Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID ISC.LRM1002-E is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.feig.de/en/downloads-support/declarations-of-conformity.html...
  • Page 20: Usa (Fcc) And Canada (Ic)

    Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. Installation with FCC / IC Approval: FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand- ards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification.
  • Page 21: Label Information Reader Modul Id Isc.lrm1002-E

    Identification Integration Manual ID ISC.LRM1002-E 5.2.1 Label Information Reader Modul ID ISC.LRM1002-E The following information has to be mount outside on the housing of the reader. 5.2.2 USA (FCC) and Canada (IC) approved antennas This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with maxi- mum permission gain and required antenna impedance for each antenna type indicated.
  • Page 22: Technical Data

    Identification Integration Manual ID ISC.LRM1002-E Technical Data Mechanical Data  Dimensions ( W x H x D ) 160 x 120 x 35 mm³ 6,29 x 4,72 x 1,37 inch³  Weight Approx. 0,35 kg 0,77 lb Electrical Data  Supply Voltage ...
  • Page 23 Identification Integration Manual ID ISC.LRM1002-E   Supported Transponders ISO15693, ISO18000-3 MODE 1 (EM HF ISO Chips, Fujitsu HF ISO Chips, KSW Sensor Chips, IDS Sensor Chips, Infineon my-d, NXP I-Code, STM ISO Chips, TI Tag-it)  ISO18000-3M3 (Upgrade Code required) ...

This manual is also suitable for:

Id isc.lr1002-e

Table of Contents