LG niagara4 MultiSITE Edge 10 User Manual page 44

Table of Contents

Advertisement

Name
Value
Locale
string
Engine Watch- dog
Log Only, Terminate (default),
Policy
Reboot
Engine Watch- dog
00000h 03m (default)
Timeout
Enable Station Auto-
Enable (default)/disable
Save
Station Auto- Save
00024h 00m (default)
Frequency
Station Auto- Save
0
Versions to Keep
RAM Disk
Min Free 5 (default), Size,
Status
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Description
Determines locale-specific behavior such as date and time formatting, and also
which lexicons are used. A string entered must use the form: language ["_"
country ["_" variant]]
For example U.S. English is "en_US" and traditional Spanish would be
"es_ES_Traditional".
For related details, see Oracle documentation at http://docs.
oracle.com/javase/1.4.2/docs/api/java/util/Locale.html
Defines response taken by the platform daemon if it detects a station engine
watchdog timeout. With the watchdog, the station periodically reports to the
platform daemon its updated engine cycle count. The watchdog purpose is to
detect and deal with a "hung" or "stalled" station, and is automatically enabled
when the station starts.
Log Only — Generates stack dump and logs an error message in the system
log. (The station should ultimately be restarted if a watchdog timeout occurs
with the "Log Only" setting).
Terminate — (Default) Kills the VM process. If "restart on failure" is enabled
for the station (typical), the station is restarted.
Reboot — Automatically reboots the host MS-E10 device platform. If "auto-
start" is enabled for the station, the station is restarted after the system
reboots.
In Niagara 4.x, the range is from 1 minute to many hours.
If the station's engine cycle count stops changing and/or the station does not
report a cycle count to the platform daemon within this defined period, the
platform daemon causes the VM to generate a stack dump for diagnostic
purposes, then takes the action defined by the Engine Watchdog Policy.
Allows for "auto save" of running station to "config_back-
up_<YYMMDD>_<HHMM>.bog" file at the frequency defined in next property.
Auto-saved backup files are kept under that station's folder.
Default is every 24 hours for any embedded MS-E10 device, range is from 1 to
many hours.
Range is 1–10. The oldest of kept backups is replaced upon next manual save
or auto-save backup, once the specified limit is reached. Significant flash
space is saved by keeping this 0 or perhaps 1.
Min Free — Default is 5. Sets the level at which Platform Services and
Platform Admin show a warning.
Size — Default is 64MB. Indicates the size of RAM disk used to store history
and alarm files.
Status — current status of RAM disk
MS- E10 User Guide