Configuring System Passphrase - LG niagara4 MultiSITE Edge 10 User Manual

Table of Contents

Advertisement

policies).
In any case, note that only one LAN port can be set as DHCP. If enabling LAN2, you must specify another (network)
static IP address and the appropriate subnet mask, i.e. a different subnet mask for each enabled LAN port IP
address.
The device does not provide IP routing or bridging operation between different Interfaces.

Configuring system passphrase

In this Commissioning Wizard step, specify a passphrase to replace the factory default passphrase. A strong password is
required (a minimum of 10 characters and include at least one uppercase character, at least one lowercase character, and at
least one digit).
In Niagara 4.4 and later, Workbench requires that the user remove the default platform user account and change the default
system passphrase prior to completing a platform connection. These requirements are configurable via the Platform Connections
options under Tools→Options.
Figure 20: Platform connection options
These platform connection options are "true" by default, so that anytime Workbench detects either of the following
conditions when making a platform connection it launches the Change Platform Defaults Wizard which steps you
through the required changes:
The system passphrase of the remote platform is the default value.
The platform credentials of the remote platform are factory default values.
This view allows you to configure whether or not the system prompts the user to remove the default platform user account and/or
to change the default system passphrase when making a platform connection. These options are offered as a convenience. For
example, if another workflow already prompts for these changes, setting one or both of these options to false can prevent
redundant prompts.
The system passphrase is used to protect sensitive information stored on all Niagara systems. The system passphrase is
assigned as the file passphrase for "portable" files, such as backups and station copies, and is used to encrypt those files. During
operations in which you transfer encrypted files to a system (restoring backups, transferring a station, etc.) you are prompted to
enter the file passphrase if it doesn't match the system passphrase for the target system. For more details, see "System
passphrase" in the Niagara Platform Guide.
Step 1
Enter the Current Passphrase for the MS-E10 device (typically the factory default passphrase).
Step 2
Enter a strong password in the New Passphrase and Confirm New Passphrase fields.
The entries in both of these fields must match.
Step 3
Click Next to continue.
Due to our policy of continuous product innovation, some specifications may change without notification.