UPSI-IP-1 Series
OUTPUT DATA – NORMAL MODE
Unless otherwise stated, all specifications apply to 25° C ambient temperature,
12 or 24 V DC input voltage and nominal output current (I
Output voltage
Output voltage range
Capacitive load
Output current
I
N
I
STAT.BOOST
I
DYN.BOOST
I
SFB
Output power
P
(U
, I
= I
, I
N
N
OUT
N
CHARGE
P
(U
, I
= I
STAT.BOOST
N
OUT
P
(U
, I
= I
DYN.BOOST
N
OUT
Short-circuit proof
No-load proof
Overcurrent shutdown
Revision 1
UPSI-1208IP-11U
12 V DC
U
OUT
(depending on load)
3000 μF (at start)
8 A
8.4 A
8.5...9.5 A for max. 3 s
30 A (5 ms)
= 0)
91.5 W
, I
= 0)
96 W
STAT.BOOST
CHARGE
, I
= 0)
98...108.5 W for max. 3 s
DYN.BOOST
CHARGE
Yes
Yes
8.5...9.5 A for max. 3 s;
9.6...10.8 A for max. 100 ms;
>10.8 A for max. 5 ms
).
N
= U
– 0.5 V DC max.
IN
UPSI-2406IP-12U
24 V DC
U
= U
– 0.4 V DC max.
OUT
IN
(depending on load)
6 A
6.3 A
6.4...7.5 A for max. 3 s
30 A (5 ms)
142 W
148.5 W
150...176 W for max. 3 s
Yes
Yes
6.4...7.5 A for max. 3 s;
7.6...10.8 A for max. 100 ms;
>10.8 A for max. 5 ms