Thermo Scientific Emerald Wireless Remote Sensor Supplemental User Manual

Thermo Scientific Emerald Wireless Remote Sensor Supplemental User Manual

Advertisement

Quick Links

Compatible Sensors for Smart-Vue
Pro Duo / Quatro Data Logger
Emerald Wireless Remote Sensor
Triple - CO
, Temperature and Humidity Sensor
2
Differential Pressure Sensor
Supplemental User Guide
331942H01 • Revision
B • 12/21/2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Emerald Wireless Remote Sensor and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Thermo Scientific Emerald Wireless Remote Sensor

  • Page 1 Compatible Sensors for Smart-Vue Pro Duo / Quatro Data Logger Emerald Wireless Remote Sensor Triple - CO , Temperature and Humidity Sensor Differential Pressure Sensor Supplemental User Guide 331942H01 • Revision B • 12/21/2020...
  • Page 2 IMPORTANT Read this instruction manual. Failure to follow the instructions in this manual can result in damage to the unit, injury to operating personnel, and poor equipment performance. CAUTION All internal adjustments and maintenance must be performed by qualified service personnel. Material in this manual is for informational purposes only.
  • Page 3: Table Of Contents

    Wireless Remote Sensor Calibration......10 Key Specifications ............ 11 Inserting the Battery into your Emerald Sensor ..11 Activating an Emerald Wireless Remote Sensor..11 Mounting your Emerald Sensor ........ 12 Using Adhesive Tape..........12 Using Wireless Remote Sensors with your Data Loggers ............
  • Page 4 Differential Pressure Smart Sensor ....... 22 Overview ..............22 Usage ..............22 Tube Placement ............23 Key Specifications ............ 24 Placement and Assembly ......... 24 Velcro location on Extension box......25 Appendix 1 - Troubleshooting ........26 Appendix 2 – Emerald Battery Life ....... 29 Battery Details............
  • Page 5: Notices And Safety

    Never dispose of improper operation, disconnect it immediately from its power batteries in fire. Do not charge regular batteries that source or remove the battery and contact Thermo Scientific are not specifically rechargeable. When the battery technical services.
  • Page 6: Device Maintenance

    Device Maintenance CAUTION: Do not attempt to disassemble the device. There are no user serviceable parts inside. CAUTION: Do not misuse the device. Follow instructions on proper operation and only use as intended. Misuse could make the device inoperable, damage the device and / or other equipment or harm users.
  • Page 7: Emerald Wireless Remote Sensor

    Emerald Wireless Remote Battery Warning Sensor CAUTION: This product contains a lithium battery. Make sure you respect polarity (+/-) when inserting batteries into OCEASOFT devices. Reversing Disclaimer and Limitation of polarity by inserting the batteries incorrectly can cause the product to heat up, and may lead to Liability battery liquid leakage.
  • Page 8: Certifications And Compliance

    This paragraph pertains to 915 MHz Smart-Vue Pro™ This paragraph pertains to 868 MHz Smart-Vue Pro™ wireless devices. This device complies with part 15 of the wireless devices. The Thermo Scientific product (contains FCC rules. Operation is subject to the following two Bluetooth component BMD-300, LoRaWAN component...
  • Page 9 Certain Hazardous Substances in Electronic and Electrical Equipment) and the amendment of (EU) 2015/863. Do not dispose of this product with household trash. Thermo Scientific recycles this product under certain conditions. Contact us for more information. Compatible Sensors for Smart-Vue Pro Duo / Quatro Data Logger...
  • Page 10: Emerald Wireless Remote Sensor

    Emerald Wireless Remote Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum Sensor (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more FCC Statements...
  • Page 11 Australia / New Zealand The BMD-300 radio equipment in this device has been tested to comply with the AS/NZS 4268:2012 / AMDT 1:2013, radio equipment and systems – short range devices – limits and methods of measurement. Bluetooth • RF-PHY Component (Tested) – DID: D030629 •...
  • Page 12: Differential Pressure Smart Sensor; Temperature, Humidity And Co Smart Sensor

    Differential Pressure Smart Sensor; Temperature, Humidity and CO Smart Sensor CAUTION: This product can potentially expose you to chemicals including lead, which is known to the State of California to California cause cancer. For more information, go to Proposition 65 www.P65Warnings.ca.gov WEEE Compliance This device complies with the essential requirements and...
  • Page 13: Introduction

    Introduction This user guide covers three Smart Sensor models that are compatible with the Smart-Vue Pro data logger: • Emerald Bluetooth connected wireless remote sensor • Triple - CO , Temperature and Humidity sensor • Differential pressure sensor. The focus in this document is mainly on physical / hardware aspects of the Smart Sensors listed above.
  • Page 14: Emerald Bluetooth Enabled Wireless Remote Sensors

    Smart-Vue Pro Quatro. For the Smart-Vue Pro data logger to detect your nearby Emerald wireless remote sensor, you must first activate Bluetooth on the sensor as described below. The Smart-Vue Pro data logger cannot discover a wireless remote sensor if it is disabled or in standby mode.
  • Page 15: Key Specifications

    Follow these steps to insert or replace the battery. In order for a Smart-Vue Pro data logger to be able to detect an Emerald wireless remote sensor, you must first activate the sensor as described here: 1. The Lithium battery...
  • Page 16: Mounting Your Emerald Sensor

    Using Adhesive Tape Identifying the Strong Side of the Magnet You may also choose to mount the Emerald sensor using the provided adhesive tape. The magnet has a “weak” side and a “strong” side. Here is a Note: Clean the magnet before using the adhesive tape on it. hint to help you identify which side is which: the metal ring inside the hole is close to the edge on the “weak”...
  • Page 17 If a problem occurs during the pairing procedure, check the Activating an Emerald Wireless Remote Sensor. If the instructions in Appendix 1 - Troubleshooting before Emerald module is activated, you may need to wait a few attempting to pair again.
  • Page 18 With your Smart-Vue Pro data logger, you may directly swap wired sensors that are physically connected to your data To reset the Emerald wireless remote sensor’s battery logger such as for recalibration or to replace damaged cables. counter (only after removing or replacing batteries), use the Wired sensors may be replaced at any time whether data Reset battery option on your Smart-Vue Pro data logger.
  • Page 19: Wireless Remote Sensors In Smart-Vue Pro Web Application

    6. A confirmation message is shown when the process is complete. Figure 12. Choose the current wireless remote sensor you want to replace Figure 14. Confirmation message that the swap 5. Tap to highlight the sensor to use (which must already be process is complete paired with your Smart-Vue Pro data logger) and tap OK to confirm.
  • Page 20 Wireless Remote Sensor on the Data Logger If not done already: 1. Pair the wireless remote sensor with your Smart-Vue Pro data logger as described in Pairing a Bluetooth Wireless Remote Sensor. Figure 16. Wireless remote sensor shown in 2. Create the Smart-Vue Pro data logger in the web sensor list application by entering its serial number.
  • Page 21: Maintaining Your Emerald Wireless Remote Sensors

    4. Enter your password and define settings as necessary for • To benefit from a full year of operation we recommend your data logging session. storing emerald modules between about 20°C and 30°C (68°F and 86°F). 5. Click Start to launch data logging using the wireless remote sensor.
  • Page 22: Co , Temperature And Humidity Smart Sensor

    , Temperature and Humidity Smart Sensor Overview The complete kit is shown here (Smart-Vue Pro data logger sold separately): The CO , temperature and humidity Smart Sensor is a triple- function device with three sensors. This Smart Sensor is designed to be placed upright inside an incubator and connected via the provided ribbon cable to a Smart-Vue Pro data logger placed outside the incubator.
  • Page 23: Key Specifications

    Placing the Sensor and The CO sensor is contained inside the casing with the dual temperature and humidity sensor attached to the back, as Smart-Vue Pro Data shown here: Logger Don’t press the detector Follow these instructions to assemble and place your triple opening sensor unit.
  • Page 24 3. Clip the Smart Sensor extension firmly onto the bottom of 5. Connect the Smart Sensor extension cable to the sensor the Smart-Vue Pro data logger. ribbon cable: Round cable to Ribbon cable to Smart Sensor sensor unit extension Figure 28. Join the sensor cables together 6.
  • Page 25 user guide and use the provided cable holders to attach or coil the excess cable neatly. CAUTION: When routing sensor cables, avoid direct contact with or close proximity of sensor cabling with any high voltage wiring. Cabling should be placed with no less than a minimum of 2 inches (50 mm) distance from high voltage components.
  • Page 26: Differential Pressure Smart Sensor

    Differential Pressure Smart Sensor Overview The differential pressure Smart Sensor extension clips on to the bottom of your Smart-Vue Pro data logger enabling you to compare the difference in pressure between two physically Smart Vue Pro separated spaces. The sensor detects the difference in placement atmospheric pressure between where the Smart-Vue Pro is outside...
  • Page 27: Tube Placement

    Smart-Vue Pro placement outside airlock Figure 34. High pressure cleanroom with an airlock Figure 36. Monitoring a high pressure cleanroom and low pressure cleanroom CAUTION: One of the input pairs must always be Smart-Vue Pro left open. placement outside airlock The complete kit is shown here (Smart-Vue Pro data logger sold separately): Figure 35.
  • Page 28: Key Specifications

    The various components in the Figure 37 are as follows: the room to be monitored and connect the other end to the appropriate (+ or -) connector on the data logger. Table 2. Description of Figure 37 2. Clip the Smart Sensor extension firmly onto the bottom of S.No Description the Smart-Vue Pro data logger.
  • Page 29: Velcro Location On Extension Box

    Velcro location on Extension box Figure 39. Velcro location Compatible Sensors for Smart-Vue Pro Duo / Quatro Data Logger Differential Pressure Smart Sensor |...
  • Page 30: Appendix 1 - Troubleshooting

    Appendix 1 - Troubleshooting If you are having difficulties with your configuration, refer to To pair the wireless remote sensor with your Smart-Vue Pro these frequently asked questions before contacting technical data logger, follow these instructions: support. 1. Remove the battery from the Emerald module and The wireless remote sensor I wish to pair does not replace the battery (to deactivate “remote”...
  • Page 31 2. When the battery is removed / discharged completely. user needs to reset the sensor (remove the battery and insert This is observed as sensor unreachable in Smart-Vue Pro back again) to complete the unpairing process. Then user can data logger. pair the sensor again to the Smart-Vue Pro Duo/Quatro.
  • Page 32 Does the Emerald device send a low battery alert to the data logger? Emerald low battery indication is not shown on Smart-Vue Pro Duo/Quatro data logger, but Emerald low batery status / level are send to Webapp as described in section Wireless Remote Sensor Battery Indication.
  • Page 33: Appendix 2 - Emerald Battery Life

    • System: Primary Li-Thionyl / Chloride / LiSOCI2 CAUTION: Use only batteries recommended by Thermo Scientific. Incorrect batteries may cause the device to heat up, and may result in a fire or battery liquid leakage. Compatible Sensors for Smart-Vue Pro Duo / Quatro Data Logger...
  • Page 34 Ulteriori informazioni sulla conformità di Thermo Fisher Scientific con queste Direttive, l’elenco delle ditte di riciclaggio nel Vostro paese e informazioni sui prodotti Thermo Scientific che pos- sono essere utili alla rilevazione di sostanze soggette alla Direttiva RoHS sono disponibili sul sito www.thermofisher.com/WEEERoHS.
  • Page 35 IF YOU NEED ASSISTANCE: Thermo Fisher Scientific products are backed by a global technical support team ready to support your applications. We offer cold storage accessories, including remote alarms, temperature recorders, and validation services. Visit www.thermofisher.com/cold or call: Countries Sales North America +1 866 984 3766 India toll free...