SECTION 4: OPERATION
Vanair Mfg., Inc. recommends that the
following procedure is used for routine
shutdowns in order to keep the system in
optimal condition, and minimimize undue
stress that may occur during the next start up
session if some of the machine conditions
were left in working mode(s) or had auxiliary
power draws left intact (such as a tool
receptacle left plugged into the generator,
etc.).
To prepare the machine for shutdown:
1. Shut off any tools or other items that
are drawing power from the
generator, or compressed air from
the air tank.
2. Close all service valves.
3. Unplug any power cords that are
plugged into the generator panel.
4. Turn the Generator and Welder
switches on the control panel
(Figure 4-2, [B & G]) to their OFF
positions.
5. Allow machine to run at idle for a 3-
5 minutes to allow for a cool down
sequence.
6. Turn the Engine Control Switch to
the OFF position [A
are present, the engine should start
TABLE 4A: ENGINE THROTTLE CONTROL FUNCTION CONDITIONS
Pressure Setting
Tank Pressure Below (<)
100 PSI or Set Pressure
Tank Pressure Above (>)
100 PSI or Set Pressure
I
Any combination of the 150 Power System output functions (compressor, generator, welder) used simultaneously at
capacity will have an adverse affect on engine running at full throttle.
II
Factory set pressure: 95 PSI = ON / 125 PSI = OFF
PAGE - 20
]. If no air leaks
1
Generator
Welder Switch
Switch
OFF
OFF
II
OFF
OFF
II
OFF
ON
OFF
ON
090043-OP_r0 (MARCH - 2015)
at idle speed the next time it is
started.
Refer to Engine Owner's Manual for
additional information pertaining to the
4.3 ENGINE THROTTLE
CONTROL FUNCTIONS
The engine speed is controlled by three
factors:
1. The level of air pressure in the tank
and the position of the pilot valve
adjustment switch (refer to Figure
4-4).
2. The position of the welder switch on
the unit control panel, and the use
of the welder.
3. The position of the generator switch
on the control panel.
Consult Table 4A: Engine Throttle Control
Function Conditions to understand how the
engine speed relates to the demand(s) of the
machine system's output functions.
I
Engine Speed Condition Result
Engine runs at full throttle.
Engine runs at idle speed, ready for application.
ON
Welder can be activated by striking an arc with engine
running at full throttle and button is depressed on
electrode holder.
Engine runs at full throttle speed (3600 RPM);
generator is ready for use.
ON
Full speed and all items available for use.
®
AIR N ARC
150 SERIES
NOTE
starting of the engine.
VANAIR MANUFACTURING, INC.
(800) 526-8817 • www.vanair.com