Engine Start-Up; Engine Shutdown - Vanair ALL-IN-ONE POWER SYSTEM AIR N ARC 150 Series Operations Manual & Parts List

Welder, generator, air compressor, battery booster
Table of Contents

Advertisement

SECTION 4: OPERATION
A
ON
OFF
GENER ATOR
A
2
A
A
1
3
H
KEY
A
ELECTRIC ENGINE KEY START
A
OFF POSITION
1
A
ON POSITION
2
A
START POSITION
3
B
AC GENERATOR ON/OFF
C
AC VOLTAGE OUTLET (240 V)
D
VOLTS DISPLAY METER
E
RESETTABLE CIRCUIT BREAKERS (15A)
F
AC VOLTAGE OUTLETS (120 V)
G
DC WELDER GENERATOR ON/ORR

4.2.1 ENGINE START-UP

1. Check to make sure all switches (for
Welder and Generator) are in the
OFF position prior to starting
(Consult Figure 4-2 and Figure 4-
3.)
Air compressor will start automatically
with machine start-up.
2. Turn the engine control switch from
the OFF position to the ON position.
3. Continue turning control switch to
the START position [A
engine starts (when the switch is let
go, it will revert back to ON
position).
PAGE - 18
B
C
D E F G
WELDER
J
DESCRIPTION
Figure 4-2: Instrumentation
NOTE
] until the
3
090043-OP_r0 (MARCH - 2015)
ON
OFF
L
K
M
KEY
H
LOW FUEL LIGHT
J
6-PIN WELDER LEAD CONNECTOR
K
AIR PRESSURE GAUGE
L
(OPTIONAL) BATTERY CHARGE PLUG
M
BATTERY CABLE AND WELD CABLE
RECEPTACLE
N
ENGINE OFF
P
ENGINE ON
Q
ENGINE START
R
ENGINE FAULT
S
ENGINE CHOKE
4. Let engine run at idle for a 3-5
minutes to allow for warm up
sequence.

4.2.2 ENGINE SHUTDOWN

Consult Figure 4-2. To shut the engine off at
any time, turn the engine control switch to
the OFF position [A
is best reserved for emergency shutdown
situations only.
Compressors and engines generate heat
and create hot surfaces. Use caution
AIR N ARC
DESCRIPTION
]. However, this method
1
CAUTION
when operating and servicing
equipment. Some surfaces and
components may be hot.
VANAIR MANUFACTURING, INC.
(800) 526-8817 • www.vanair.com
®
150 SERIES
N
P
Q
R
S

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents