Performance Tests
E5092A Performance Test Record
Load Match, Insertion Loss and Isolation Test for Switch 3 (SP4T, Port
3, 3A, 3B, 3C and 3D)
Load Match (Unselected)
Port
Frequency
(Selected
Range [Hz]
Port)
3B (3A)
50M to 3G
3G to 10G
10G to 16G
16G to 18G
18G to 20G
3C (3A)
50M to 3G
3G to 10G
10G to 16G
16G to 18G
18G to 20G
3D (3A)
50M to 3G
3G to 10G
10G to 16G
16G to 18G
18G to 20G
3A (3B)
50M to 3G
3G to 10G
10G to 16G
16G to 18G
18G to 20G
3C (3B)
50M to 3G
3G to 10G
10G to 16G
16G to 18G
18G to 20G
78
Test Limit
Test Result [dB]
[dB]
< -17.0
< -11.0
< -8.0
< -6.0
< -4.0
< -17.0
< -11.0
< -8.0
< -6.0
< -4.0
< -17.0
< -11.0
< -8.0
< -6.0
< -4.0
< -17.0
< -11.0
< -8.0
< -6.0
< -4.0
< -17.0
< -11.0
< -8.0
< -6.0
< -4.0
Measurement
Uncertainty
[dB]
± 0.43
± 0.37
± 0.28
± 0.28
± 0.35
± 0.43
± 0.37
± 0.28
± 0.28
± 0.35
± 0.43
± 0.37
± 0.28
± 0.28
± 0.35
± 0.43
± 0.37
± 0.28
± 0.28
± 0.35
± 0.43
± 0.37
± 0.28
± 0.28
± 0.35